IE-4000-4TC4G-E Switch with 4 FE Copper combo ports and 4 GE combo uplink ports
€4,041.92
Features |
Robust industrial design |
● Built for harsh environment and temperature range (-40 to 70 C).
● Hardened for vibration, shock and surge, and noise immunity.
● Resilient dual ring design via 4x Gigabit Ethernet uplink ports.
● Complies with multi-industry specifications for automation, ITS, and substation environments.
● Improves uptime, performance, and safety of industrial systems and equipment.
● Fitted with compact, DIN rail compliant form factor ideal for industrial deployment.
● Covers a wide range of Power over Ethernet (PoE) application requirements.
|
User-friendly GUI device manager |
● Allows easy configuration and monitoring via a web based device manager.
● Eliminates the need for more complex terminal emulation programs.
● Reduces the cost of deployment.
● Multiple Language Support — English, Chinese (Traditional), Chinese (Simplified), French, German, Japanese, Spanish (LATAM)
|
SwapDrive: “zero-config” replacement |
● Simple switch replacement in case of a failure.
● No networking expertise required.
● Helps ensure fast recovery.
|
High-density industrial Power over Ethernet (PoE) |
● Reduces complexity with one cable for both connectivity and power.
● Controls costs by limiting wiring, distribution panels, and circuit breakers.
● Creates space and reduces heat dissipation.
● Enables ready-to-use PoE devices like IP phones and wireless access points.
● Supports (on select models) maximum HD camera deployments.
● Designed to support PoE power budget up to 240W (Refer Table 2 for details)
|
Full Gigabit Ethernet switch |
● Connects new wireless access point (802.11n and 802.11ac).
● Enables new HD IP Cameras and new PLC (Programmable Logic Control).
● Allows SCADA (Supervisory Control And Data Acquisition) connectivity.
● Provides introduction of new bandwidth-hungry applications in the industrial space.
● Supports very-delay-sensitive applications and time-sensitive networks.
● Delivers multiple rings, redundant ring topology for new network configurations.
● Extends geographical scalability where longer distance connectivity is required.
|
⠀
Hardware configurations |
Product number |
Total ports |
GE combo (SFP or RJ45) uplinks (4G)1 |
Additional combo (SFP or RJ45) ports |
Default software License |
|||
IE-4000-4TC4G-E |
8 |
All models have 4 GE combo uplink ports |
4 FE |
|
|
|
All models ship with LAN Base feature set2 |
⠀
Power supplies |
Product Number |
Wattage |
Rated nominal input operating range |
PoE/PoE support1 |
|
PWR-IE50W-AC= |
50W |
AC 100-240V/1.25A 50-60Hz or DC 125-250V/1.25A |
No |
|
PWR-IE50W-AC-L= 2 |
50W |
AC 100-240V/1.2A 50-60Hz |
No |
|
PWR-IE65W-PC-AC= |
65W |
AC 100-240V/1.4A 50-60Hz or DC 125-250V/1.0A |
Yes |
|
PWR-IE65W-PC-DC= |
65W |
DC 24-48VDC/4.5A |
Yes |
|
PWR-IE170W-PC-AC= |
170W |
AC 100-240V/2.3A 50-60Hz or DC 125-250V/2.1A |
Yes |
|
PWR-IE170W-PC-DC= |
170W |
DC 12-54VDC/2.3A |
Yes |
|
PWR-IE240W-PCAC-L= 2 |
240W |
AC 100-240V/3.5A 50-60Hz |
Yes |
|
PWR-IE480W-PCAC-L= 2 |
480W |
AC 100-240V/6.0A 50-60Hz |
Yes |
Product specifications |
Hardware |
● 1GB DRAM
● 128-MB onboard flash memory
● 1-GB removable SD flash memory card (Included)
● Mini-USB connector
● RJ-45 connector
|
Alarm |
● Alarm I/O: two alarm inputs to detect dry contact open or closed, one alarm output relay
|
⠀
Power specifications |
Input voltage range |
Redundant DC input voltage: nominal 9.6 to 60VDC |
Maximum Input current |
4.3A |
Power consumption1 |
40W |
1These numbers are measured at 9.6V and do not include PoE power consumption.
⠀
Physical specifications |
Dimensions (H x W x D) |
6.12 x 6.12 x 5.09 in. (155.4 x 155.4 x 129.2 mm) |
||
Weight |
6.35 pounds (2.88 kg) |
Switch performance and scalability |
Forwarding rate |
Line rate for all ports and all packet sizes |
Number of queues |
4 egress |
Unicast MAC addresses |
16,000 |
IGMP multicast groups |
1,000 |
Number of VLANs |
1,000 |
IPv4 MAC security ACEs |
1,000 with default TCAM Template |
NAT translation |
Bidirectional, 128 unique subnet NAT translation entries, which can expand to tens of thousands of translated entries if designed properly |
⠀
Cisco IE 4000 LAN Base: Key software features |
LAN Base license (default) |
Features |
Layer 2 switching |
IEEE 802.1, 802.3, 802.3at, 802.3af standard, VTPv2, NTP, UDLD, CDP, LLDP, Unicast Mac filter, Flexlink, Resilient Ethernet Protocol (REP), VTPv3, EtherChannel, Voice VLAN, QinQ tunneling, Industrial macro configuration |
Security |
SCP, SSH, SNMPv3, TACACS , RADIUS Server/Client, MAC Address Notification, BPDU Guard, Port-Security, Private VLAN, DHCP Snooping, Dynamic ARP Inspection, IP Source Guard, 802.1x, Guest VLAN, MAC Authentication Bypass, 802.1x Multi-Domain Authentication, Storm Control, Trust Boundary, FIPS 140-2, ACT2, Secure boot, Full flexible Netflow1 |
Layer 2 multicast |
IGMPv1, v2, v3 Snooping, IGMP filtering, IGMP Querier |
Management |
Fast Boot, Express setup, Web Device Manager, Industrial Network Director (IND), MIB, Smartport, SNMP, syslog, storm control, unicast, multicast, broadcast, SPAN sessions, RSPAN, DHCP server, customized DOM (digital optical management), Embedded Event Manager (EEM), Plug-n-Play Agent, Port-based DHCP |
Industrial Ethernet |
CIP Ethernet/IP, Profinet v2, IEEE 1588 PTP v2, NTP to PTP translation, CIP Time Sync |
Quality of service |
Ingress Policing, Rate-Limit, Egress Queueing/shaping, AutoQoS, QoS, PROFINET QoS |
Layer 2 IPv6 |
IPv6 Host support, HTTP over IPv6, SNMP over IPv6 |
Layer 3 routing |
IPv4 Static Routing |
Industrial management |
Layer 2 switching with 1:1 static Network Address Translation (NAT) |
Redundancy |
Redundancy Ethernet Protocol ring (REP) Parallel Redundancy Protocol (PRP) Media Redundancy Protocol (MRP) ring, MRP Auto Manager (MAM) High Availability Seamless Redundancy (HSR), PTP over HSR HSR-PRP (Dual RedBox mode) HSR-HSR (Quadbox) |
Utility |
Power Profile, dying gasp, GOOSE messaging, SCADA protocol classification, MODBUS TCP/IP, utility SmartPort macro, BFD, Ethernet OAM, IEEE 802.3ah, CFM (IEEE 802.1ag) |
⠀
Cisco IE 4000 IP Services: Key software features |
IP Services license |
Additional features |
IP multicast |
PIM sparse mode (PIM-SM), PIM dense mode (PIM-DM), and PIM sparse-dense mode |
IP unicast routing protocols |
OSPF, EIGRP, BGPv4, IS-IS, RIPv2, Policy-Based Routing (PBR), HSRP |
IPv6 routing |
RIPng, OSPFv6, and EIGRPv6 support |
Security |
IEEE 802.1AE MACsec (including PSK based MKA support), Cisco TrustSec®, SGT inline tagging and SGACL, Full flexible Netflow |
Virtualization |
VRF-lite |
⠀
Cisco IE 4000 DNA Essentials license features |
Feature |
Description |
Cisco DNA Center |
Discovery, topology, inventory, software image management |
Visibility |
Cisco DNA assurance, full flexible Netflow, Device 360 |
Day-zero network bring-up automation |
Cisco Network Plug-and-Play application |
⠀
Cisco IE 4000 DNA Advantage license features |
Feature |
Description |
Cisco DNA Essentials |
All Cisco DNA Essentials features |
Software-defined access |
Policy based automation, IE 4000 can function as an SD-Access extended node |
⠀
Compliance specifications |
Type |
Standards |
Electromagnetic emissions |
FCC 47 CFR Part 15 Class A EN 55022A Class A EN 300 386 VCCI Class A AS/NZS CISPR 22 Class A CISPR 11 Class A CISPR 22 Class A ICES 003 Class A CNS13438 Class A KN22 |
Electromagnetic immunity |
EN55024 CISPR 24 AS/NZS CISPR 24 KN24 EN 61000-4-2 Electro Static Discharge EN 61000-4-3 Radiated RF EN 61000-4-4 Electromagnetic Fast Transients N 61000-4-5 Surge EN 61000-4-6 Conducted RF EN 61000-4-8 Power Frequency Magnetic Field EN 61000-4-9 Pulse Magnetic Field EN 61000-4-10 Damped Oscillatory Magnetic Field (100 A/m) EN 61000-4-11 AC Power Voltage EN 61000-4-18 Damped Oscillatory Wave EN-61000-4-29 DC Voltage Dips |
Industry standards |
EN 61000-6-1 Light Industrial EN 61000-6-2 Industrial EN 61000-6-4 Industrial EN 61326 Industrial Control EN 61131-2 Programmable Controllers Substation KEMA (IEEE 1613, IEC 61850-3) Marine DNV GL – (Ships; High speed and light craft) NEMA TS-2 (EMC, environmental, mechanical) IEEE 1613 Electric Power Stations Communications Networking IEC 61850-3 Electric Substations Communications Networking EN50155 Railway — Electronic Equipment on Rolling Stock (EMC, ENV, Mech) EN50121-4 Railway — Signaling and Telecommunications Apparatus EN50121-3-2 Railway — Apparatus for Rolling Stock ODVA Industrial EtherNet/IP PROFINET conformance B IP30 (per EN60529) |
Safety standards and certifications |
Information Technology Equipment: UL/CSA 60950-1 EN 60950-1 CB to IEC 60950-1 with all country deviations NOM to NOM-019-SCFI (through partners and distributor) Industrial Floor (Control Equipment): UL 508 CSA C22.2, No 142 Hazardous Locations: ANSI/ISA 12.12.01 CSA C22.2 No 213 IEC 60079-0, -15 IECEx test report EN 60079-0, -15 ATEX certification (Class I Zone 2) Cabinet enclosure required |
Operating environment |
Operating Temperature: -40C to 75C ● -40C to 70C (Vented Enclosure Operating)
● -40C to 60C (Sealed Enclosure Operating)
● -34C to 75C (Fan or Blower equipped Enclosure Operating)
EN 60068-2-1 EN 60068-2-2 EN 61163 Altitude: up to 15,000 feet |
Storage environment |
Temperature: -40 to 85 degrees C Altitude: 15,000 feet IEC 60068-2-14 |
Humidity |
Relative humidity of 5% to 95% non-condensing IEC 60068-2-3 IEC 60068-2-30 |
Shock and vibration |
IEC 60068-2-27 (operational shock, 50G, 11ms, Half Sine) IEC 60068-2-27 (Non-Operational Shock, 65-80G, 9ms, Trapezoidal) IEC 60068-2-6, IEC 60068-2-64, EN 61373 (Operational Vibration) IEC 60068-2-6, IEC 60068-2-64, EN 61373 (Non-operational Vibration) |
Corrosion |
ISO 9223: Corrosion class C3-Medium class C4-High EN 60068-2-52 (Salt Fog) EN 60068-2-60 (Flowing Mixed Gas) |
Others |
RoHS Compliance China RoHS Compliance TAA (Government) CE (Europe) |
Warranty |
Five-year limited HW warranty on all IE-4000 PIDs and all IE Power Supplies (see table 3 above). See link below for more details on warranty |
Mean Time Between Failures (MTBF) |
IE-4000-4TC4G-E: 578, 730 Hours IE-4000-8T4G-E: 591, 070 Hours IE-4000-8S4G-E: 583, 700 Hours IE-4000-4T4P4G-E: 562, 300 Hours IE-4000-16T4G-E: 558, 310 Hours IE-4000-4S8P4G-E: 535, 880 Hours IE-4000-8GT4G-E: 591, 240 Hours IE-4000-8GS4G-E: 583, 700 Hours IE-4000-4GC4GP4G-E: 550, 940 Hours IE-4000-16GT4G-E: 558, 630 Hours IE-4000-8GT8GP4G-E: 519, 190 Hours IE-4000-4GS8GP4G-E: 536, 220 Hours |
⠀
Management and standards |
Description |
Specification |
|
IEEE standards |
● IEEE 802.1D MAC Bridges, STP
● IEEE 802.1p Layer2 COS prioritization
● IEEE 802.1q VLAN
● IEEE 802.1s Multiple Spanning-Trees
● IEEE 802.1w Rapid Spanning-Tree
● IEEE 802.1x Port Access Authentication
● IEEE 802.1AB LLDP
● IEEE 802.3ad Link Aggregation (LACP)
● IEEE 802.3af Power over Ethernet provides up to 15.4W DC power to each end device
● IEEE 802.3at Power over Ethernet provides up to 25.5W DC power to each end device
|
● IEEE 802.3af Power over Ethernet
● IEEE 802.3at Power over Ethernet Plus
● IEEE 802.3ah 100BASE-X SMF/MMF only
● IEEE 802.3x full duplex on 10BASE-T
● IEEE 802.3 10BASE-T specification
● IEEE 802.3u 100BASE-TX specification
● IEEE 802.3ab 1000BASE-T specification
● IEEE 802.3z 1000BASE-X specification
● IEEE 1588v2 PTP Precision Time Protocol
● IEEE 802.1AS PTP
● IEEE 802.1Qbv TSN
|
RFC compliance |
● RFC 768: UDP
● RFC 783: TFTP
● RFC 791: IPv4 protocol
● RFC 792: ICMP
● RFC 793: TCP
● RFC 826: ARP
● RFC 854: Telnet
● RFC 951: BOOTP
● RFC 959: FTP
● RFC 1157: SNMPv1
● RFC 1901,1902-1907 SNMPv2
● RFC 2273-2275: SNMPv3
● RFC 2571: SNMP Management
● RFC 1166: IP Addresses
● RFC 1256: ICMP Router Discovery
|
● RFC 1305: NTP
● RFC 1492: TACACS
● RFC 1493: Bridge MIB Objects
● RFC 1534: DHCP and BOOTP interoperation
● RFC 1542: Bootstrap Protocol
● RFC 1643: Ethernet Interface MIB
● RFC 1757: RMON
● RFC 2068: HTTP
● RFC 2131, 2132: DHCP
● RFC 2236: IGMP v2
● RFC 3376: IGMP v3
● RFC 2474: DiffServ Precedence
● RFC 3046: DHCP Relay Agent Information Option
● RFC 3580: 802.1x RADIUS
● RFC 4250-4252 SSH Protocol
|
SNMP MIB objects |
● BRIDGE-MIB
● CALISTA-DPA-MIB
● CISCO-ACCESS-ENVMON-MIB
● CISCO-ADMISSION-POLICY-MIB
● CISCO-AUTH-FRAMEWORK-MIB
● CISCO-BRIDGE-EXT-MIB
● CISCO-BULK-FILE-MIB
● CISCO-CABLE-DIAG-MIB
● CISCO-CALLHOME-MIB
● CISCO-CAR-MIB
● CISCO-CDP-MIB
● CISCO-CIRCUIT-INTERFACE-MIB
● CISCO-CLUSTER-MIB
● CISCO-CONFIG-COPY-MIB
● CISCO-CONFIG-MAN-MIB
● CISCO-DATA-COLLECTION-MIB
● CISCO-DHCP-SNOOPING-MIB
● CISCO-EMBEDDED-EVENT-MGR-MIB
● CISCO-ENTITY-ALARM-MIB
● CISCO-ENTITY-SENSOR-MIB
● CISCO-ENTITY-VENDORTYPE-OID-MIB
● CISCO-ENVMON-MIB
● CISCO-ERR-DISABLE-MIB
● CISCO-FLASH-MIB
● CISCO-FTP-CLIENT-MIB
● CISCO-IF-EXTENSION-MIB
● CISCO-IGMP-FILTER-MIB
● CISCO-IMAGE-MIB
● CISCO-IP-STAT-MIB
● CISCO-LAG-MIB
● CISCO-LICENSE-MGMT-MIB
● CISCO-MAC-AUTH-BYPASS-MIB
● CISCO-MAC-NOTIFICATION-MIB
● CISCO-MEMORY-POOL-MIB
● CISCO-PAE-MIB
● CISCO-PAGP-MIB
● CISCO-PING-MIB
● CISCO-PORT-QOS-MIB
● CISCO-PORT-SECURITY-MIB
● CISCO-PORT-STORM-CONTROL-MIB
● CISCO-PRIVATE-VLAN-MIB
● CISCO-PROCESS-MIB
● CISCO-PRODUCTS-MIB
● CISCO-RESILIENT-ETHERNET-PROTOCOL-MIB
● CISCO-RTTMON-ICMP-MIB
● CISCO-RTTMON-IP-EXT-MIB
● CISCO-RTTMON-MIB
● CISCO RTTMON-RTP-MIB
|
● CISCO RTTMON-RTP-MIB
● CISCO-SNMP-TARGET-EXT-MIB
● CISCO-STACK-MIB
● CISCO-STACKMAKER-MIB
● CISCO-STP-EXTENSIONS-MIB
● CISCO-SYSLOG-MIB
● CISCO-TCP-MIB
● CISCO-UDLDP-MIB
● CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB
● CISCO-VLAN-MEMBERSHIP-MIB
● CISCO-VTP-MIB
● ENTITY-MIB
● ETHERLIKE-MIB
● HC-RMON-MIB
● IEEE8021-PAE-MIB
● IEEE8023-LAG-MIB
● IF-MIB
● IP-FORWARD-MIB
● LLDP-EXT-MED-MIB
● LLDP-EXT-PNO-MIB
● LLDP-MIB
● NETRANGER
● NOTIFICATION-LOG-MIB
● OLD-CISCO-CHASSIS-MIB
● OLD-CISCO-CPU-MIB
● OLD-CISCO-FLASH-MIB
● OLD-CISCO-INTERFACES-MIB
● OLD-CISCO-IP-MIB
● OLD-CISCO-MEMORY-MIB
● OLD-CISCO-SYS-MIB<
● OLD-CISCO-SYSTEM-MIB
● OLD-CISCO-TCP-MIB
● OLD-CISCO-TS-MIB
● RMON-MIB
● RMON2-MIB
● SMON-MIB
● SNMP-COMMUNITY-MIB
● SNMP-FRAMEWORK-MIB
● SNMP-MPD-MIB
● SNMP-NOTIFICATION-MIB
● SNMP-PROXY-MIB
● SNMP-TARGET-MIB
● SNMP-USM-MIB
● SNMP-VIEW-BASED-ACM-MIB
● SNMPv2-MIB
● TCP-MIB
● UDP-MIB
|
⠀
SFP support |
Part number |
Specification |
SFP type |
Max distance |
Cable type |
Temp range* |
DOM support |
GLC-FE-100FX-RGD= |
100BASE-FX |
FE |
2km |
MMF |
IND |
Yes |
GLC-FE-100LX-RGD= |
100BASE-LX10 |
FE |
10km |
SMF |
IND |
Yes |
GLC-FE-100FX= |
100BASE-FX |
FE |
2km |
MMF |
COM |
No |
GLC-FE-100LX= |
100BASE-LX10 |
FE |
10km |
SMF |
COM |
No |
GLC-FE-100EX= |
100BASE-EX |
FE |
40km |
SMF |
COM |
No |
GLC-FE-100ZX= |
100BASE-ZX |
FE |
80km |
SMF |
COM |
No |
GLC-FE-100BX-D= |
100BASE-BX10 |
FE |
10km |
SMF |
COM |
No |
GLC-FE-100BX-U= |
100BASE-BX10 |
FE |
10km |
SMF |
COM |
Yes |
GLC-SX-MM-RGD= |
1000BASE-SX |
GE |
550m |
MMF |
IND |
Yes |
GLC-LX-SM-RGD= |
1000BASE-LX/LH |
GE |
550m/10km |
MMF/SMF |
IND |
Yes |
GLC-ZX-SM-RGD= |
1000BASE-ZX |
GE |
70km |
SMF |
IND |
Yes |
GLC-BX40-U-I= |
1000BASE-BX40 |
GE |
40km |
SMF |
IND |
Yes |
GLC-BX40-D-I= |
1000BASE-BX40 |
GE |
40km |
SMF |
IND |
Yes |
GLC-BX40-DA-I= |
1000BASE-BX40 |
GE |
40km |
SMF |
IND |
Yes |
GLC-BX80-U-I= |
1000BASE-BX80 |
GE |
80km |
SMF |
IND |
Yes |
GLC-BX80-D-I= |
1000BASE-BX80 |
GE |
80km |
SMF |
IND |
Yes |
GLC-SX-MMD= |
1000BASE-SX |
GE |
550m |
MMF |
EXT |
Yes |
GLC-LH-SMD= |
1000BASE-LX/LH |
GE |
550m/10km |
MMF/SMF |
EXT |
Yes |
GLC-EX-SMD= |
1000BASE-EX |
GE |
40km |
SMF |
EXT |
Yes |
GLC-ZX-SMD= |
1000BASE-ZX |
GE |
70km |
SMF |
EXT |
Yes |
GLC-BX-D= |
1000BASE-BX10 |
GE |
10km |
SMF |
COM |
Yes |
GLC-BX-U= |
1000BASE-BX10 |
GE |
10km |
SMF |
COM |
Yes |
CWDM-SFP-xxxx= (8 freq) |
CWDM 1000BASE-X |
GE |
|
SMF |
COM |
Yes |
DWDM-SFP-xxxx= (40 freq) |
DWDM 1000BASE-X |
GE |
|
SMF |
COM |
Yes |
SFP-GE-S= |
1000BASE-SX |
GE |
550m |
MMF |
EXT |
Yes |
SFP-GE-L= |
1000BASE-LX/LH |
GE |
550m/10km |
MMF/SMF |
EXT |
Yes |
SFP-GE-Z= |
1000BASE-ZX |
GE |
70km |
SMF |
EXT |
Yes |
GLC-SX-MM= |
1000BASE-SX |
GE |
550m |
MMF |
COM |
No |
GLC-LH-SM= |
1000BASE-LX/LH |
GE |
550m/10km |
MMF/SMF |
COM |
No |
GLC-ZX-SM= |
1000BASE-ZX |
GE |
70km |
SMF |
COM |
Yes |
GLC-TE= |
1000BASE-T |
GE |
100m |
Copper |
EXT |
NA |
GLC-T-RGD= |
1000BASE-T |
GE |
100m |
Copper |
IND |
NA |
GLC-BX-U-I= |
1000BASE-BX |
GE |
10km |
SMF |
IND |
Yes |
GLC-BX-D-I= |
1000BASE-BX |
GE |
10km |
SMF |
IND |
Yes |