Cisco Industrial Ethernet IE-4010-16S12P
733,261.00₽
Features |
Robust industrial design |
● A utility grade, fully managed 1 RU rack mount Ethernet access switch with PoE capabilities.
● Fanless, convection cooled with no moving parts.
● Extended operational temperature range (-40 to 75C).
● Hardened for vibration, shock, surge, and electrical noise immunity.
● Complies with multi-industry specifications for industrial automation, ITS, and electrical substation environments.
● Improves uptime, performance, and safety of industrial systems and equipment.
● IEEE 1588v2 PTP (both power profile for utility and default profile for manufacturing are supported).
● Alarm I/O for monitoring and signaling to external equipment.
|
User-friendly GUI device manager |
● Allows easily configuration and monitoring via a web browser.
● Eliminates the need for terminal emulation programs.
● Multiple Language Support — English, Chinese (Traditional), Chinese (Simplified), French, German, Japanese, Spanish (LATAM)
|
Swap drive: zero — config replacement |
● Simple switch replacement in case of a failure.
● No networking expertise required.
● Helps ensure fast recovery.
|
High-density industrial Power over Ethernet (PoE/PoE ) |
● Supports up to 24 total PoE/PoE ports with power budget up to 385W available with two power supplies.
● Enables ready-to-use PoE devices, such as High Definition (HD) IP cameras, wireless access points, and IP phones.
|
Complete Gigabit Ethernet switch |
● Total of 28 Gigabit Ethernet ports provide multiple resilient design options.
● Connects new wireless access point (802.11n and 802.11ac).
● Enables new HD IP cameras and future proof Gigabit speed automation devices.
● Allows IP-based Supervisory Control And Data Acquisition (SCADA) connectivity.
● Supports very-delay-sensitive applications and time-sensitive networks.
● Delivers multiple rings; redundant ring topology for new network configurations.
● Extends geographical scalability where longer distance connectivity is required.
|
⠀
Hardware configurations |
Product number |
Total ports |
SFP Uplinks |
SFP fiber ports (S) |
Copper PoE/PoE Ports2(P) |
Default software |
IE-4010-16S12P |
28 |
4 FE/GE |
12 FE/GE |
12 FE/GE |
LAN Base1 |
Power supplies for Cisco IE 4010 Series Switches |
Product number |
Wattage |
Rated nominal input operating range |
Supported input voltage operating range |
PoE/PoE support |
Use case scenario |
PWR-RGD-AC-DC-H |
150W |
AC 100-240V/2.0A 50-60Hz or DC 100-250V/2.0A |
AC 85-264V or DC 88-300V |
Yes |
High voltage AC or DC power source, for hazardous locations PoE power application |
PWR-RGD-LOW-DC-H |
150W |
DC 24-60V/10A |
DC 18-75V |
Yes |
Low voltage DC power source, for hazardous locations PoE power application |
PWR-RGD-AC-DC-250 |
250W |
AC 100-240V 3.3A 50-60Hz or DC 100-250V 3.3A |
AC 85-264V or DC 88-300V |
Yes |
High voltage AC or DC power source, for hazardous locations PoE power application |
⠀
Available power budget for PoE/PoE with different power supply wattage |
Product number |
150W |
150W (dual) |
250W |
250W 150W |
250W (dual) |
IE-4010-16S12P |
80 |
200 |
180 |
285 |
360 |
⠀
Product specifications |
Hardware |
● 1 GB DRAM
● 128 MB onboard flash memory
● 1-GB removable SD flash memory card (Included)
● Mini-USB and traditional RJ-45 console connector
|
Alarm |
Alarm I/O: four alarm inputs to detect dry contact open or closed, one Form C alarm output relay |
Accessories |
● SD-IE-1GB= — Spare SD card
● L-IE4000-RTU= — Electronic RTU IP services software license for 4010 switches
● 21–in. and 23–in. ETSI rack mount brackets
|
⠀
Physical specifications |
Dimensions, (H x W x D) |
● 1.75 x 17.5 x 14.0 in. (4.45 x 44.5 x 35.6 cm) with PWR-RGD-AC-DC-H / PWR-RGD-LOW-DC-H
● 1.75 x 17.5 x 15.18 in. (4.45 x 44.5 x 38.56 cm) with PWR-RGD-AC-DC-250
|
|
System Weight |
Without power supply: 12.7 lb (5.78 kg) |
|
Power Supply Weight |
● PWR-RGD-AC-DC-H: 2.55 lb (1.16 kg)
● PWR-RGD-LOW-DC-H: 2.5 lb (1.13 kg)
● PWR-RGD-AC-DC-250: 3.1 lb (1.4 kg)
|
|
Power consumption |
Maximum of 70W not including PoE consumption |
⠀
Switch performance and scalability |
Forwarding bandwidth |
28 Gbps (line rate/non-blocking) |
Switching bandwidth |
56 Gbps(Switching bandwidth is full-duplex capacity) |
Forwarding rate |
41.67 mpps with 64 byte packets (line rate for all ports and packet sizes) |
Number of queues |
4 egress |
Unicast MAC addresses |
16,000 |
IGMP multicast groups |
1000 |
Number of VLANs |
1000 |
IPv4 MAC security ACEs |
1000 with default TCAM template |
NAT translation |
Bidirectional, 128 unique subnet NAT translation entries, which can expand to tens of thousands of translated entries if designed properly |
⠀
Cisco IE 4010 LAN base license: Key software features |
LAN base license (default) |
Features |
Layer 2 switching |
IEEE 802.1, 802.3, 802.3at, 802.3af standard, VTPv2, NTP, UDLD, CDP, LLDP, Unicast Mac filter, Flexlink, VTPv3, EtherChannel, Voice VLAN, QinQ tunneling |
Security |
SCP, SSH, SNMPv3, TACACS , RADIUS Server/Client, MAC Address Notification, BPDU Guard, Port-Security, Private VLAN, DHCP Snooping, Dynamic ARP Inspection, IP Source Guard, 802.1x, Guest VLAN, MAC Authentication Bypass, 802.1x Multi-Domain Authentication, Storm Control, Trust Boundary, Cisco TrustSec®security, FIPS 140-2, ACT2, Secure Boot, Full flexible Netflow1 |
Layer 2 multicast |
IGMPv1, v2, v3 Snooping, IGMP filtering, IGMP Querier |
Management |
Fast Boot, Express Setup, HTTP Web Config, SmartPort, MIB, SNMP, syslog, Storm Control—Unicast, Multicast, Broadcast, SPAN Sessions, RSPAN, DHCP Server, Energywise, PnP, Customized TCAM/SDM size configuration, DOM (digital optical management), Port-based DHCP |
Industrial Ethernet |
CIP Ethernet/IP, Profinet v2, IEEE 1588 PTP v2 Default Profile |
Quality of Service (QoS) |
Ingress Policing, Rate-Limit, Egress Queueing/shaping, AutoQoS, Modular QoS CLI (MQC),PROFINET QoS |
Layer 2 IPv6 |
IPv6 Host support, HTTP over IPv6, SNMP over IPv6 |
Layer 3 routing |
IPv4 Static Routing |
Industrial management |
Layer 2 switching with 1:1 static Network Address Translation (NAT) |
Utility |
IEEE 1588v2 PTP Power Profile, dying gasp, GOOSE messaging, SCADA protocol classification, MODBUS TCP/IP Memory Maps, utility SmartPort macro, BFD, Ethernet OAM, IEEE 802.3ah, CFM (IEEE 802.1ag) |
Redundancy |
Redundancy Ethernet Protocol ring (REP) Parallel Redundancy Protocol (PRP) High Availability Seamless Redundancy (HSR), PTP over HSR Media Redundancy Protocol (MRP) ring, MRP Auto Manager (MAM) |
⠀
Cisco IE 4010 IP Services license: Key software features |
IP services license |
Additional features |
IP multicast |
PIM Sparse Mode (PIM-SM), PIM Dense Mode (PIM-DM), and PIM sparse-dense mode |
Industrial management |
Embedded Event Manager (EEM) |
IP unicast routing protocols |
OSPF, EIGRP, BGPv4, IS-IS, RIPv2, Policy-Based Routing (PBR), HSRP |
IPv6 routing |
RIPng, OSPFv6, and EIGRPv6 support |
Security |
IEEE 802.1AE MACsec (including PSK based MKA support), Cisco TrustSec®, SGT inline tagging and SGACL, Full flexible Netflow |
Virtualization |
VRF-lite |
⠀
Cisco IE 4010 DNA Essentials features |
Feature |
Description |
Cisco DNA Center |
Discovery, topology, inventory, software image management |
Visibility |
Cisco DNA assurance, Full flexible Netflow, Device 360 |
Day-zero network bring-up automation |
Cisco Network Plug-and-Play application |
⠀
Cisco IE 4010 DNA Advantage features |
Feature |
Description |
DNA Essentials |
All DNA Essentials features |
Software-Defined Access (SDA) |
Policy based automation, IE 4010 can function as an SDA extended node |
⠀
Compliance specifications |
Type |
Standards |
Electromagnetic emissions |
FCC 47 CFR Part 15 Class A EN 55022A Class A VCCI Class A AS/NZS CISPR 22 Class A CISPR 11 Class A CISPR 22 Class A ICES 003 Class A EN 300 386 CNS13438 Class A (pending) |
Electromagnetic immunity |
EN55024 CISPR 24 AS/NZS CISPR 24 EN 61000-4-2 Electro Static Discharge EN 61000-4-3 Radiated RF EN 61000-4-4 Electromagnetic Fast Transients EN 61000-4-5 Surge EN 61000-4-6 Conducted RF EN 61000-4-8 Power Frequency Magnetic Field EN 61000-4-9 Pulse Magnetic Field EN 61000-4-10 Damped Oscillatory Magnetic Field (100 A/m) EN 61000-4-11 AC Power Voltage EN 61000-4-18 Damped Oscillatory Wave EN-61000-4-29 DC Voltage Dips |
Industry standards |
EN 61000-6-1 Light Industrial EN 61000-6-2 Industrial EN 61000-6-4 Industrial EN 61326 Industrial Control EN 61131-2 Programmable Controllers IEEE 1613 Electric Power Stations Communications Networking IEC 61850-3 Communication networks for power utility automation EN50121-4 Railway — Signaling and Telecommunications Apparatus EN50121-3-2 Railway — Apparatus for Rolling Stock PROFINET conformance B IP30 Marine DNV GL — Ships NEMA TS-2 (EMC, environmental, mechanical) |
Safety standards and certifications |
Information technology equipment: UL/CSA 60950-1 EN 60950-1 CB to IEC 60950-1 with all country deviations NOM to NOM-019-SCFI (through partners and distributor) Industrial floor (control equipment): UL 508 UL 61010-2 CSA C22.2, No 142 Hazardous locations: Class 1, Div2, gas groups IIC ANSI/ISA 12.12.01 CSA C22.2 No 213 IEC 60079-0, -15 IECEx test report EN 60079-0, -15 ATEX certification (Class I Zone 2) (Cabinet enclosure required) |
Operating environment |
Operating Temperature: -40C to 75C ● -40C to 70C (Vented Enclosure — 40 LFM Air Flow)
● -40C to 60C (Sealed Enclosure — 0 LFM Air Flow)
● -34C to 75C (Fan or Blower equipped Enclosure — 200 LFM Air Flow)
● -40C to 85C (IEC 60068-2-2 Environmental Type Testing, 16 hours)
● Operating altitude: Up to 13,800ft
● EN 60068-2-1, EN 61163
|
Storage environment |
Temperature: -40C to 85C Altitude: Up to 15,000 feet IEC 60068-2-14 |
Humidity |
Relative humidity of 5% to 95% noncondensing IEC 60068-2-3 IEC 60068-2-30 |
Shock and vibration |
IEC 60068-2-27 (operational shock, 50G, 11ms, Half Sine) IEC 60068-2-27 (Non-Operational Shock, 65-80G, 9ms, Trapezoidal) IEC 60068-2-6, IEC 60068-2-64, EN 61373 (Operational Vibration) IEC 60068-2-6, IEC 60068-2-64, EN 61373 (Nonoperational Vibration) |
Corrosion |
ISO 9223: Corrosion lass C3-Medium class C4-High EN 60068-2-52 EN 60068-2-60 (Flowing Mixed Gas) |
Others |
RoHS Compliance China RoHS Compliance TAA (Government) CE (Europe) |
Warranty |
Five-year limited hardware warranty on all IE-4010 PIDs and power supplies (see Table 3). See link that follows for more details on warranty. |
Mean Time Between Failures (MTBF) |
IE-4010-4S24P: 429,620 hours IE-4010-16S12P: 415,160 hours |
⠀
Management and standards |
Description |
Specification |
|
IEEE standards |
● IEEE 802.1D MAC Bridges, STP
● IEEE 802.1p Layer2 COS prioritization
● IEEE 802.1q VLAN
● IEEE 802.1s Multiple Spanning-Trees
● IEEE 802.1w Rapid Spanning-Tree
● IEEE 802.1x Port Access Authentication
● IEEE 802.1AB LLDP
● IEEE 802.3ad Link Aggregation (LACP)
● IEEE 802.3af Power over Ethernet provides up to 15.4W DC power to each end device
● IEEE 802.3at Power over Ethernet provides up to 25.5W DC power to each end device
|
● IEEE 802.3af Power over Ethernet
● IEEE 802.3at Power over Ethernet Plus
● IEEE 802.3ah 100BASE-X SMF/MMF only
● IEEE 802.3x full duplex on 10BASE-T
● IEEE 802.3 10BASE-T specification
● IEEE 802.3u 100BASE-TX specification
● IEEE 802.3ab 1000BASE-T specification
● IEEE 802.3z 1000BASE-X specification
● IEEE 1588v2 PTP Precision Time Protocol
|
RFC compliance |
● RFC 768: UDP
● RFC 783: TFTP
● RFC 791: IPv4 protocol
● RFC 792: ICMP
● RFC 793: TCP
● RFC 826: ARP
● RFC 854: Telnet
● RFC 951: BOOTP
● RFC 959: FTP
● RFC 1157: SNMPv1
● RFC 1901,1902-1907 SNMPv2
● RFC 2273-2275: SNMPv3
● RFC 2571: SNMP Management
● RFC 1166: IP Addresses
● RFC 1256: ICMP Router Discovery
|
● RFC 1305: NTP
● RFC 1492: TACACS
● RFC 1493: Bridge MIB Objects
● RFC 1534: DHCP and BOOTP interoperation
● RFC 1542: Bootstrap Protocol
● RFC 1643: Ethernet Interface MIB
● RFC 1757: RMON
● RFC 2068: HTTP
● RFC 2131, 2132: DHCP
● RFC 2236: IGMP v2
● RFC 3376: IGMP v3
● RFC 2474: DiffServ Precedence
● RFC 3046: DHCP Relay Agent Information Option
● RFC 3580: 802.1x RADIUS
● RFC 4250-4252 SSH Protocol
|
SNMP MIB objects |
● BRIDGE-MIB
● CALISTA-DPA-MIB
● CISCO-ACCESS-ENVMON-MIB
● CISCO-ADMISSION-POLICY-MIB
● CISCO-AUTH-FRAMEWORK-MIB
● CISCO-BRIDGE-EXT-MIB
● CISCO-BULK-FILE-MIB
● CISCO-CABLE-DIAG-MIB
● CISCO-CALLHOME-MIB
● CISCO-CAR-MIB
● CISCO-CDP-MIB
● CISCO-CIRCUIT-INTERFACE-MIB
● CISCO-CLUSTER-MIB
● CISCO-CONFIG-COPY-MIB
● CISCO-CONFIG-MAN-MIB
● CISCO-DATA-COLLECTION-MIB
● CISCO-DHCP-SNOOPING-MIB
● CISCO-EMBEDDED-EVENT-MGR-MIB
● CISCO-ENTITY-ALARM-MIB
● CISCO-ENTITY-VENDORTYPE-OID-MIB
● CISCO-ENVMON-MIB
● CISCO-ERR-DISABLE-MIB
● CISCO-FLASH-MIB
● CISCO-FTP-CLIENT-MIB
● CISCO-IGMP-FILTER-MIB
● CISCO-IMAGE-MIB
● CISCO-IP-STAT-MIB
● CISCO-LAG-MIB
● CISCO-LICENSE-MGMT-MIB
● CISCO-MAC-AUTH-BYPASS-MIB
● CISCO-MAC-NOTIFICATION-MIB
● CISCO-MEMORY-POOL-MIB
● CISCO-PAE-MIB
● CISCO-PAGP-MIB
● CISCO-PING-MIB
● CISCO-PORT-QOS-MIB
● CISCO-PORT-SECURITY-MIB
● CISCO-PORT-STORM-CONTROL-MIB
● CISCO-PRIVATE-VLAN-MIB
● CISCO-PROCESS-MIB
● CISCO-PRODUCTS-MIB
● CISCO-RESILIENT-ETHERNET-PROTOCOL-MIB
● CISCO-RTTMON-ICMP-MIB
● CISCO-RTTMON-IP-EXT-MIB
● CISCO-RTTMON-MIB
● CISCO-RTTMON-RTP-MIB
|
● CISCO-SNMP-TARGET-EXT-MIB
● CISCO-STACK-MIB
● CISCO-STACKMAKER-MIB
● CISCO-STP-EXTENSIONS-MIB
● CISCO-SYSLOG-MIB
● CISCO-TCP-MIB
● CISCO-UDLDP-MIB
● CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB
● CISCO-VLAN-MEMBERSHIP-MIB
● CISCO-VTP-MIB
● ENTITY-MIB
● ETHERLIKE-MIB
● HC-RMON-MIB
● IEEE8021-PAE-MIB
● IEEE8023-LAG-MIB
● IF-MIB
● IP-FORWARD-MIB
● LLDP-EXT-MED-MIB
● LLDP-EXT-PNO-MIB
● LLDP-MIB
● NETRANGER
● NOTIFICATION-LOG-MIB
● OLD-CISCO-CHASSIS-MIB
● OLD-CISCO-CPU-MIB
● OLD-CISCO-FLASH-MIB
● OLD-CISCO-INTERFACES-MIB
● OLD-CISCO-IP-MIB
● OLD-CISCO-MEMORY-MIB
● OLD-CISCO-SYS-MIB<
● OLD-CISCO-SYSTEM-MIB
● OLD-CISCO-TCP-MIB
● OLD-CISCO-TS-MIB
● RMON-MIB
● RMON2-MIB
● SMON-MIB
● SNMP-COMMUNITY-MIB
● SNMP-FRAMEWORK-MIB
● SNMP-MPD-MIB
● SNMP-NOTIFICATION-MIB
● SNMP-PROXY-MIB
● SNMP-TARGET-MIB
● SNMP-USM-MIB
● SNMP-VIEW-BASED-ACM-MIB
● SNMPv2-MIB
● TCP-MIB
● UDP-MIB
|
⠀
SFP support |
Part number |
Specification |
SFP type |
Max distance |
Cable type |
Temp range* |
DOM support |
GLC-FE-100FX-RGD= |
100BASE-FX |
FE |
2 km |
MMF |
IND |
Yes |
GLC-FE-100LX-RGD= |
100BASE-LX10 |
FE |
10 km |
SMF |
IND |
Yes |
GLC-FE-100FX= |
100BASE-FX |
FE |
2 km |
MMF |
COM |
No |
GLC-FE-100LX= |
100BASE-LX10 |
FE |
10 km |
SMF |
COM |
No |
GLC-FE-100EX= |
100BASE-EX |
FE |
40 km |
SMF |
COM |
No |
GLC-FE-100ZX= |
100BASE-ZX |
FE |
80 km |
SMF |
COM |
No |
GLC-FE-100BX-D= |
100BASE-BX10 |
FE |
10 km |
SMF |
COM |
No |
GLC-FE-100BX-U= |
100BASE-BX10 |
FE |
10 km |
SMF |
COM |
Yes |
GLC-SX-MM-RGD= |
1000BASE-SX |
GE |
550 m |
MMF |
IND |
Yes |
GLC-LX-SM-RGD= |
1000BASE-LX/LH |
GE |
550 m/10 km |
MMF/SMF |
IND |
Yes |
GLC-ZX-SM-RGD= |
1000BASE-ZX |
GE |
70 km |
SMF |
IND |
Yes |
GLC-BX-U-I= |
1000BASE-BX |
GE |
10 km |
SMF |
IND |
Yes |
GLC-BX-D-I= |
1000BASE-BX |
GE |
10 km |
SMF |
IND |
Yes |
GLC-BX40-U-I= |
1000BASE-BX40 |
GE |
40 km |
SMF |
IND |
Yes |
GLC-BX40-D-I= |
1000BASE-BX40 |
GE |
40 km |
SMF |
IND |
Yes |
GLC-BX40-DA-I= |
1000BASE-BX40 |
GE |
40km |
SMF |
IND |
Yes |
GLC-BX80-U-I= |
1000BASE-BX80 |
GE |
80km |
SMF |
IND |
Yes |
GLC-BX80-D-I= |
1000BASE-BX80 |
GE |
80km |
SMF |
IND |
Yes |
GLC-SX-MMD= |
1000BASE-SX |
GE |
550m |
MMF |
EXT |
Yes |
GLC-LH-SMD= |
1000BASE-LX/LH |
GE |
550m/10km |
MMF/SMF |
EXT |
Yes |
GLC-EX-SMD= |
1000BASE-EX |
GE |
40 km |
SMF |
EXT |
Yes |
GLC-ZX-SMD= |
1000BASE-ZX |
GE |
70 km |
SMF |
EXT |
Yes |
GLC-BX-D= |
1000BASE-BX10 |
GE |
10 km |
SMF |
COM |
Yes |
GLC-BX-U= |
1000BASE-BX10 |
GE |
10 km |
SMF |
COM |
Yes |
CWDM-SFP-xxxx= (8 freq) |
CWDM 1000BASE-X |
GE |
|
SMF |
COM |
Yes |
DWDM-SFP-xxxx= (40 freq) |
DWDM 1000BASE-X |
GE |
|
SMF |
COM |
Yes |
SFP-GE-S= |
1000BASE-SX |
GE |
550 m |
MMF |
EXT |
Yes |
SFP-GE-L= |
1000BASE-LX/LH |
GE |
550 m/10 km |
MMF/SMF |
EXT |
Yes |
SFP-GE-Z= |
1000BASE-ZX |
GE |
70 km |
SMF |
EXT |
Yes |
GLC-SX-MM= |
1000BASE-SX |
GE |
550 m |
MMF |
COM |
No |
GLC-LH-SM= |
1000BASE-LX/LH |
GE |
550 m/10 km |
MMF/SMF |
COM |
No |
GLC-ZX-SM= |
1000BASE-ZX |
GE |
70 km |
SMF |
COM |
Yes |
GLC-TE= |
1000BASE-T |
GE |
100 m |
Copper |
EXT |
NA |
GLC-T= |
1000BASE-T |
GE |
100 m |
Copper |
COM |
NA |
GLC-T-RGD= |
1000BASE-T |
GE |
100 m |
Copper |
IND |
NA |