Cisco Industrial Ethernet IE-1000-8P2S-LM

2,552.00$

Power Supplies

SmartNet

Сумма:

Add-ons total:

Всего:

Вес: 0 kg
скачать как CSV

Hardware configurations

Product Number

Total Ports

GE SFP Uplink

PoE/PoE

PoE Budget

Input Power Voltage

IE-1000-8P2S-LM

10

2

8

180W

48-54V

Power Supplies

Product Number

Wattage

Rated nominal input operating range

PoE/PoE support1

PWR-IE50W-AC=

50W

AC 100-240V/1.25A 50-60Hz
or
DC 125-250V/1.25A

No

PWR-IE50W-AC-L=2

50W

AC 100-240V/1.2A 50-60Hz

No

PWR-IE65W-PC-AC=

65W

AC 100-240V/1.4A 50-60Hz
or
DC 125-250V/1.0A

Yes

PWR-IE65W-PC-DC=

65W

DC 24-48VDC/4.5A

Yes

PWR-IE170W-PC- AC=

170W

AC 100-240V/2.3A 50-60Hz
or
DC 125-250V/2.1A

Yes

PWR-IE170W-PC- DC=

170W

DC 12-54VDC/2.3A

Yes

PWR-IE240W-PCAC-L=2

240W

AC 100-240V/3.5A 50-60Hz

Yes

PWR-IE480W-PCAC-L=2

480W

AC 100-240V/6.0A 50-60Hz

Yes

STK-RACK- DINRAIL=

19 in. DIN Rail mount kit

1 The entire power budget for the switch and PoE ports needs to stay within the power supply.
2 The power supplies are not certified for smart grid and hazardous locations. These power supplies are IP20 rated.

Product specifications

Hardware

●  DRAM: 128 MB DDR2 without ECC
●  Onboard flash memory: 160 MB

Alarm

●  Alarm I/O: output connector on top panel of 4P2S and 8P2S, 1.0A@24VDC or 0.5A@48VDC

Power consumption

●  IE1000-8P2S: without PoE 10.6W, with PoE 134.4-205.2W

Connectors and cabling

●  100BASE-FX MMF (2 km)—TBD with engineer input
●  10/100/1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling

Dimensions (H x W x D) including DIN rail

●  IE-1000-8P2S-LM: 5.0”H x 1.8” W x 5.3”D (127mm H x 45.7mmW x 134mm D)

Weight

●  IE-1000-8P2S-LM — 1.85 lb (0.84 kg)

Cisco IE 1000 Software features

Software features

LLDP, Cisco CDP aware, MSTP, STP Portfast, ICMP Vlans, static IP, Trust Ingress DSCP, COS, Priority Port, port — security, IGMP querier, DHCP server SNMP v2/v3, SNMP traps, syslog, IGMP snooping, DHCP snooping, BPDU guard, Etherchannel, Alarms, PoE capability, Smartport Macro, SPAN/Port Mirroring, Strom Control, EtherNet/IP (EDS)

Compliance specifications

Description

Specification

Safety Certifications

●  UL/CSA 60950-1
●  EN 60950-1
●  CB to IEC 60950-1 (with country deviations)
●  NOM to NOM-019-SCF1 (through partners and distributors)
●  UL/CSA/IEC/EN 61010-2-201
●  CE Marking

Hazardous Locations

●  ANSI/ISA 12.12.01 (Class1, Div2 A-D) *
●  EN 60079-0, -15 ATEX certificate (Class 1, Zone2 A-D) *
●  IEC 60079-0, 15 (report only) *
●  UL 60079-0, 15 *
●  CAN/CSA C22.2 No. 60079-0, -15 *

* Cabinet enclosure required

EMC Emissions and Immunity Compliance

●  FCC 47 CFR Part 15 Class A
●  EN 55022/CISPR 22 Class A
●  EN 55016-1-1, -1-4, -2-3 Class AVCCI Class A
●  RoHS compliance
●  AS/NZS CISPR 22 Class A, AS/NZS CISPR 24
●  CISPR11 Class A, CISPR22 Class A
●  ICES 003 Class A
●  KCC Marking (Korea)
●  CE Marking
●  RCM Marking (Australia/New Zealand)
●  EAC Marking (Eurasian Conformity)
●  Anatel (Brazil)
●  China NAL
●  IEC/EN/EN61000-4-2 (Electro Static Discharge), 8kV air/6kV contact
●  IEC/EN 61000-4-3 (Radiated Immunity, 10 V/m 80-2000MHz, 3V/m 2000-2700MHz)
●  IEC/EN 61000-4-4 (Fast Transients — 2kV DC power, 2kV data line, 4kv earth)
●  IEC/EN 61000-4-5 (Surge 2 kV/1 kV DC power, 2 kV shielded and unshielded data line)
●  IEC/EN 61000-4-6 (Conducted Immunity, 10 V/emf 0.15-80MHz)
●  IEC/EN 61000-4-8 (Power Frequency Magnetic Field Immunity 30A/m 60 sec, 300A/m 3 sec)
●  IEC/EN 61000-4-9 (Pulse Magnetic Field Immunity 300A/m)
●  IEC/EN 61000-4-29 (Voltage Dips Immunity)

Shock and Vibration

●  IEC 60068-2-27 (Operational Shock: 30G 11ms, half sine)
●  IEC 60068-2-27 (Non-Operational Shock 65-80G, trapezoidal)
●  IEC 60068-2-6, IEC 60068-2-64 (Operational Vibration)
●  EC 60068-2-6, IEC 60068-2-64, IEC 60068-2-47 (Non-operational Vibration)

Industry Standard

●  IEC/EN 61000-6-1 (Immunity for Light Industrial Environments)
●  IEC/EN 61000-6-2 (Immunity for Industrial Environments)
●  IEC/EN 61000-6-4 (Emissions for Industrial Environments)
●  EN 61131-2 (PLC Zone A & B, EMC/EMI, environmental, mechanical)
●  EN61326-1 (Industrial Controls)
●  Marine –TAC (Temp-A, Humid-B, Vib-A, EMC-A, Enc-A)
●  EN 50581 (RoHS)
●  China RoHS
●  EU WEEE
●  NEMA TS-2 (EMC, environmental, mechanical)
●  IP30

Humidity

●  IEC 60068 -2-3
●  IEC 60068-2-30 (Test Db)
●  Relative humidity: 5% to 95% non-condensing

Operating Temperature

●  IE-1000-8P2S-LM

◦    -40 C to 70 C (vented enclosure operating)

◦    -40 C to 60 C (sealed enclosure operating)

◦    -34 C to 75 C (fan or blower-equipped enclosure operating)

●  Operational altitude: Up to 13.8k ft
●  IEC 60068-2-1
●  IEC 60068-2-2
●  IEC 60068-2-56
●  -40 C to 85 C (storage temperature)
●  IEC 60068-2-14 (Test Nb)
●  Storage altitude: Up to 15,000 ft

Mean Time Between Failure (MTBF)

●  Meantime between failure: 374,052 hours (42.7 years)

Warranty

●  Five-year limited warranty on all IE-1000 hardware PIDs and all IE power supplies defined in Table 2 previously. See the following link for details on warranty

Management and Standards

Description

Specification

Specification

IEEE Standards

●  IEEE 802.1D MAC bridges, STP
●  IEEE 802.1p Layer 2 COS prioritization
●  IEEE 802.1q VLAN
●  IEEE 802.1s Multiple SpanningTrees
●  IEEE 802.1w Rapid SpanningTree
●  IEEE 802.1AB LLDP
●  IEEE 802.3ad Link Aggregation (LACP)
●  IEEE 802.3af
●  IEEE 802.3at
●  IEEE 802.3af Power over Ethernet
●  IEEE 802.3at Power over Ethernet Plus
●  IEEE 802.3ah 100BASE-X SMF/MMF only
●  IEEE 802.3x full duplex on 10Base-T
●  IEEE 802.3 10BASE-T specification
●  IEEE 802.3u 100BASE-TX specification
●  IEEE 802.3ab 1000BASE-T specification
●  IEEE 802.3z 1000BASE-X specification

RFC Compliance

●  RFC 768: UDP
●  RFC 783: TFTP
●  RFC 791: IPv4 protocol
●  RFC 792: ICMP
●  RFC 793: TCP
●  RFC 826: ARP
●  RFC 854: Telnet
●  RFC 951: BootP
●  RFC 959: FTP
●  RFC 1157: SNMPv1
●  RFC 1901,1902-1907: SNMPv2
●  RFC 2273-2275: SNMPv3
●  RFC 1166: IP Addresses
●  RFC 1256: ICMP Router Discovery
●  RFC 1305: NTP
●  RFC 1534: DHCP and BootP interoperation
●  RFC 1542: Bootstrap Protocol
●  RFC 1643: Ethernet Interface MIB
●  RFC 1757: RMON
●  RFC 2068: HTTP
●  RFC 2131, 2132: DHCP
●  RFC 2236: IGMP v2
●  RFC 2571: SNMP Management
●  RFC 4250-4252: SSH Protocol

SFP Transceivers

●  GLC-FE-100FX-RGD 2km/MMF
●  GLC-FE-100FX 2km/MMF
●  GLC-FE-100LX-RGD 10km/SMF
●  GLC-FE-100EX 40km/SMF
●  GLC-FE-100LX 10km/SMF
●  GLC-FE-100BX-D 10km/SMF
●  GLC-FE-100BX-U 10km/SMF
●  GLC-FE-100ZX 80km/SMF
●  GLC-T GigE Copper Transceiver
●  GLC-SX-MM-RGD 220-550m/MMF
●  GLC-SX-MM 220-550m/MMF
●  GLC-SX-MMD
●  GLC-LH-SM 550m/MMF, 10km/SMF
●  GLC-LH-SMD 550m/MMF,10km/SMF
●  GLC-LX-SM-RGD 550m/MMF, 10km/SMF
●  GLC-ZX-SM-RGD 70-100km/SMF
●  GLC-EX-SMD
●  GLC-BX-D 10km/SMF
●  GLC-BX-U 10km/SMF
●  GLC-BX40-DA 40km/Single Strand SMF
●  GLC-BX40-U 40km/Single Strand SMF
●  GLC-BX80-D 80km/Single Strand SMF
●  GLC-BX80-U 80km/Single Strand SMF
●  GLC-TE

Simple Network Management Protocol (SNMP) MIB Objects

●  MIB-II

Mechanical dimension details

IE1000-8P2S-LM