Cisco Catalyst IE-3200-8P2S-E Rugged Series

635,846.71

Memory Option

Power Supply

SmartNet

Сумма:

Add-ons total:

Всего:

Вес: 0 kg
скачать как CSV

Features

Robust industrial design

●  Built for harsh environments and temperature ranges (-40°C to 75°C)
●  Fanless, convection-cooled with no moving parts for extended durability
●  Hardened for vibration, shock and surge, and electrical noise immunity
●  Complies with multi-industry specifications for automation, ITS, and substation environments
●  Improves uptime, performance, and safety of industrial systems and equipment
●  Covers a wide range of Power over Ethernet (PoE) application requirements
●  Alarm I/O for monitoring and signaling to external equipment

Full Gigabit Ethernet interfaces

●  Provides secure access for new high-speed applications in the industrial space
●  Packs up to 10 ports of GE — 2×1 Gigabit Small Form-Factor Pluggable (SFP) uplinks, plus 8×1 Gigabit copper RJ45 downlink ports (with PoE or non PoE) in a small form-factor base system
●  Connects high-speed wireless access points (802.11n, 802.11ac)
●  Enables High-Definition (HD) IP cameras and Programmable Logic Controllers (PLC)
●  Delivers multiple rings and redundant ring topologies for new network configurations
●  Extends geographical scalability where longer-distance connectivity is required

High-density industrial Power over Ethernet (PoE)

●  Supports up to 8 PoE/PoE ports [Power budget — 240W]
●  Controls costs by limiting wiring, distribution panels, and circuit breakers
●  Reduces equipment needs, thus requiring less space and reducing heat dissipation
●  Enables ready-to-use PoE devices, such as IP phones, cameras, and wireless access points

User-friendly GUI, called WebUI

●  Allows easy configuration and monitoring
●  Eliminates the need for more complex terminal emulation programs
●  Reduces the cost of deployment

SwapDrive, a zero-configuration replacement

●  True zero-configuration and simple switch replacement in the event of a failure
●  No networking expertise required
●  Helps ensure fast recovery

 

IE3200 Hardware configurations

Product number

Total ports

10/100/1000 RJ45 Copper ports

100/1000 SFP ports

Software license (Default)

PoE/

PoE( ) budget

IE-3200-8P2S-E

10

8

2

Network Essentials

240W

 

IE3200 Hardware specifications

PoE power budget

240W1

Removable storage

USB2,3, SD card2

Alarms

2 alarms in, 1 alarm out

Console ports

1 RS-232 (via RJ-45), 1 USB Mini Type B

Power inputs

Dual DC power inputs

1 In order to achieve the 240W power budget, the minimum power requirements as specified in Table 7 for the switch need to be considered when selecting a power supply.
2 The USB and SD card are optional and are not shipped by default with the switch.
3 USB 2.0 to load system images and set configurations

IE3200 physical configurations

Dimensions (H x W x D)

6.0 in. X 3.6 in. X 5.3 in.
15.2 cm. x 9.1 cm. x 13.5 cm

Weight

3.8 lbs
1.7 kg

Mounting

DIN rail

IE3200_Front view and Top view

 

IE3200 performance and scalability features

Forwarding rate

Line rate for all ports and all packet sizes

Number of queues

8

Unicast MAC addresses

8K

Internet Group Management Protocol (IGMP) multicast groups

1K

No. of VLANs

256

Spanning Tree Protocol (STP) instances

128

Access Control Entries (PACL/VACL/RACL)

3K

DRAM

2 GB

Flash (User Accessible)

1.5 GB

SD card capacity1

4 GB

Jumbo Frames

8996 bytes

1The SD card is optional and is not shipped by default with the switch.

IE3200 power specifications

Input voltage range

Redundant DC input voltage: 9.6 to 60VDC

48VDC is required for PoE and 54VDC is required for PoE

Maximum Input current

5.5A

Power consumption1

32W

1 Power consumption for non PoE supported model is measured at 12V and for the PoE supported model is measured at 54V. Power consumption does not include PoE power.

Power supply options

Product Number

Wattage

Rated nominal input operating range

PoE/PoE support1

PWR-IE50W-AC=

50W

AC 100-240V/1.25A 50-60Hz
or
DC 125-250V/1.25A

No

PWR-IE50W-AC-IEC=

50W

AC 90-264V

No

PWR-IE50W-AC-L= 2

50W

AC 100-240V/1.2A 50-60Hz

No

PWR-IE65W-PC-AC=

65W

AC 100-240V/1.4A 50-60Hz
or
DC 125-250V/1.0A

Yes

PWR-IE65W-PC-DC=

65W

DC 24-48VDC/4.5A

Yes

PWR-IE170W-PC-AC=

170W

AC 100-240V/2.3A 50-60Hz
or
DC 125-250V/2.1A

Yes

PWR-IE170W-PC-DC=

170W

DC 12-54VDC/23A

Yes

PWR-IE240W-PCAC-L= 2

240W

AC 100-240V/3.5A 50-60Hz

Yes

PWR-IE480W-PCAC-L= 2

480W

AC 100-240V/6.0A 50-60Hz

Yes

1 The entire power budget for the switch and PoE ports needs to stay within the power supply wattage.
2 The power supplies are not certified for smart grid and hazardous locations. These power supplies are IP20 rated.

Key supported software features

Network Essentials License (Perpetual)

Features

Layer 2 switching

IEEE 802.1, 802.3 standard, NTP, UDLD, CDP, LLDP, unicast MAC filter, PAgP, LACP, VTPv2, VTPv3, EtherChannel, Q-in-Q tunneling, voice VLAN, PVST , MSTP, and RSTP

Multicast

IGMPv1, v2, v3 snooping, IGMP filtering, IGMP querier

Management

WebUI, MIB, SmartPort, SNMP, syslog, DHCP server, SPAN session, RSPAN, FSPAN, Express setup, NETCONF, RESTCONF

Security

Port security, 802.1x, Dynamic Host Configuration Protocol (DHCP) snooping, dynamic ARP inspection, IP source guard, guest VLAN, MAC authentication bypass, 802.1x multidomain authentication, storm control — unicast, multicast, broadcast, SCP, SSH, SNMPv3, TACACS , RADIUS server/client, MAC address notification, BPDU guard, SUDI 2099 (Secure Unique Device identifier), Access Lists (PACL/RACL/VACL), MACsec-128

Quality of Service (QoS)

Ingress policing, rate limit, egress queuing and shaping, auto QoS

IPv6

IPv6 host support, SNMP over IPv6, HTTP/HTTP(s) over IPv6, SNMP over IPv6, Syslog over IPv6, DHCPv6 relay source, DHCPv6 bulk lease query (RFC 5460), IPv6 stateless Auto Config, SCP/SSH, Radius, TACACS , NTP over IPv6, IPv6 VRF aware BGPv6, IPV6 ND cache expire, IPv6 support for TFTP, IPv6 DNS transport, IPv6 QoS, IPv6 FHS RA Guard, IPv6 FHS DHCPv6 Guard

Layer 3 routing

Inter-VLAN routing, static routing

Industrial Ethernet

CIP Ethernet/IP, IEEE 1588 PTP v2 (default and power), PROFINET

Redundancy

Resilient Ethernet Protocol (REP) ring, PROFINET-Media Redundancy Protocol (MRP), REP Preferred, Fast REP

Utility

Dying gasp, SCADA protocol classification — GOOSE messaging, MODBUS TCP/IP

Automation

YANG, NETCONF, RESTCONF

 

Compliance specifications

Industrial Automation Control System

IEC 62443-4-1

IEC 62443-4-2

Electromagnetic emissions

FCC 47 CFR Part 15 subpart B Class A

EN 55032/CISPR 32 Class A

VCCI Class A

AS/NZS CISPR 32 Class A

CISPR 11 Class A

ICES 003 Class A

CNS 13438 Class A

KN 32 Class A

EN 300 386

Electromagnetic immunity

CISPR 24

EN 55024

KN 35

EN 61000-4-2 Electro Static Discharge (air – 15kV, contact – 8kV)

EN 61000-4-3 Radiated RF (10V/m UTP, 20V/m STP)

EN 61000-4-4 Electromagnetic Fast Transients (4kV)

EN 61000-4-5 Surge (2KV/1KV Power, 4KV STP)

EN 61000-4-6 Conducted RF (10Vrms UTP)

EN 61000-4-10 Damped Oscillatory  Magnetic Field (100 A/m)

EN 61000-4-16 Conducted CM Disturbances (30V, Cont/300V, 1 sec)

EN 61000-4-17 Ripple Immunity DC Power (10%)

EN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz)

EN-61000-4-29 DC Voltage Dips and interruptions

Industry standards

EN 61000-6-2 Industrial Immunity

EN 61000-6-4 Industrial Emissions

EN 61000-6-1 Light Industrial Immunity

EN 61326-1 Measurement, Control and Laboratory Equipment

IEEE 1613 Electric Power Stations Communications Networking

EN/IEC 61850-3 Electric Substations Communications Networking

EN50121-4 Railway – Signaling and Telecommunications Apparatus

ODVA Industrial EtherNet/IP

NEMA TS 2-2016

IP30

Safety standards and certifications

Information technology equipment:

UL/CSA 60950-1,CB to IEC 60950-1 with all country deviations

UL/CSA 62368-1, CB to IEC 62368-1 with all country deviations2

Industrial floor (control equipment):

UL/CSA 61010-2-201

CB report and certificate to IEC/EN 61010-2-201

Hazardous locations:

UL121201 (Class l, Div 2, groups A-D)

CSA 213 (Class l, Div 2, groups A-D)

UL/CSA 60079-0, -15 (Class l, Zone 2, Gc/IIC)

IEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc/IIC)

EN 60079-0, -15 ATEX certificate (Class l, Zone 2, Gc/IIC) Cabinet enclosure required

Operating environment

Operating temperature:

-40°C to 70°C (40 LFM vented enclosure)

-40°C to 60°C (sealed enclosure)

-34°C to 75°C (Min. 200 LFM fan or blower-equipped enclosure)

85°C (type tested for 16 hours)

Altitude: Up to 15,000 feet

Storage environment

Temperature: -40°C to 85°C

Altitude: 15,000 feet

IEC 60068-2-14

Humidity

Relative humidity of 5% to 95% non-condensing

IEC 60068-2-78

IEC 60068-2-30

Shock and vibration

IEC 60068-2-27 (operational shock, 50G, 3ms, half sine)

IEC 60068-2-27 (non-operational shock, 65-80G, 9ms, trapezoidal)

MIL-STD-810, Method 514.4

IEC 60068-2-6 (vibration-sinusiodal, 5Hz-150Hz)

Corrosion

IEC 60068-2-52 (salt fog)

IEC 60068-2-60 (flowing mixed gas)

Warranty

Five-year limited hardware warranty on all IE3200 product IDs and all Industrial Ethernet (IE) power supplies. See more information under the Warranty section

 

MTBF information

Rated MTBF (hours)

613,125

 

Management and standards

IEEE standards

IEEE 802.1D MAC Bridges, STP

IEEE 802.1p Layer2 COS prioritization

IEEE 802.1q VLAN

IEEE 802.1s Multiple Spanning-Trees

IEEE 802.1w Rapid Spanning-Tree

IEEE 802.1x Port Access Authentication

IEEE 802.1AB LLDP

IEEE 1588v2 PTP Precision Time Protocol

IEEE 802.3ad Link Aggregation (LACP)

IEEE 802.3ah 100BASE-X SMF/MMF only

IEEE 802.3x full duplex on 10BASE-T

IEEE 802.3 10BASE-T specification

IEEE 802.3u 100BASE-TX specification

IEEE 802.3ab 1000BASE-T specification

IEEE 802.3z 1000BASE-X specification

IEEE 802.3af Power over Ethernet

IEEE 802.3at Power over Ethernet plus

RFC compliance

RFC 768: UDP

RFC 783: TFTP

RFC 791: IPv4 protocol

RFC 792: ICMP

RFC 793: TCP

RFC 826: ARP

RFC 854: Telnet

RFC 959: FTP

RFC 1157: SNMPv1

RFC 1901,1902-1907 SNMPv2

RFC 2273-2275: SNMPv3

RFC 2571: SNMP Management

RFC 1166: IP Addresses

RFC 1256: ICMP Router Discovery

RFC 1305: NTP

RFC 951: BootP

RFC 1492: TACACS

RFC 1493: Bridge MIB Objects

RFC 1534: DHCP and BOOTP interoperation

RFC 1542: Bootstrap Protocol

RFC 1643: Ethernet Interface MIB

RFC 1757: RMON

RFC 2068: HTTP

RFC 2131, 2132: DHCP

RFC 2236: IGMP v2

RFC 3376: IGMP v3

RFC 2474: DiffServ Precedence

RFC 3046: DHCP Relay Agent Information Option

RFC 3580: 802.1x RADIUS

RFC 4250-4252 SSH Protocol

RFC 5460: DHCPv6 bulk lease query

SNMP MIB objects

802.1X MIB

CISCO-DHCP-SNOOPING-MIB

CISCO-UDLDP-MIB

CISCO-ENVMON-MIB

CISCO-PRIVATE-VLAN-MIB

CISCO-PAE-MIB

Cisco-Port-QoS-MIB

CISCO-ERR-DISABLE-MIB

CISCO- PROCESS-MIB

LLDP-MIB

CiscoMACNotification-MIB

CISCO-CONFIG-COPY-MIB

LLDP-MED-MIB

Bridge-MIB

CISCO-CAR-MIB

CISCO-LAG-MIB

CISCO-SYSLOG-MIB

CISCO-FTP-CLIENT-MIB

CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB

CISCO-VLAN-MEMBERSHIP-MIB

Cisco-REP-MIB

CISCO-PORT-STORM-CONTROL-MIB

CISCO-CDP-MIB

CISCO-IP-STAT-MIB

CISCO-LICENSE-MGMT-MIB

CISCO-STP-EXTN-MIB

CISCO-VTP-MIB

IEEE8023-LAG-MIB

SMON-MIB

CISCO-ACCESS-ENVMON-MIB

CISCO-CALLHOME-MIB

CISCO-CONFIG-MAN-MIB

CISCO-FLASH-MIB

CISCO-ENTITY-SENSOR-MIB

IP-MIB

CISCO-PAGP-MIB

CISCO-IF-EXTENSION-MIB

CISCO-IMAGE-MIB

CISCO-MEMORY-POOL-MIB

CISCO-PING-MIB

SNMP-TARGET-EXT-MIB

IF_MIB

ENTITY-MIB

LLDP-EXT-PNO-MIB

NOTIFICATION-LOG-MIB

OLD-CISCO-CPU-MIB

ETHERLIKE-MIB

OLD-CISCO-SYSTEM-MIB

OLD-CISCO-MEMORY-MIB

RMON-MIB

SNMP-COMMUNITY-MIB

SNMP-FRAMEWORK-MIB

SNMP-PROXY-MIB

SNMP-MPD-MIB

SNMP-NOTIFICATION-MIB

SNMP-TARGET-MIB

SNMP-USM-MIB

CISCO-DATACOLLECTION-MIB

CISCO-CABLE-DIAG-MIB

CISCO -PORT-SECURITY-MIB

BULK_FILE_MIB

NAC-NAD-MIB

CISCO-ENTITY-ALARAM-MIB

SNMP-VIEW-BASED-ACM-MIB

CISCO-MAC-AUTH-BYPASS-MIB

CISCO-AUTH-FRAMEWORK-MIB

CISCO-BRIDGE-Ext-MIB

SNMPv2-MIB

CISCO-ENTITY-VENDORTYPE-OID-MIB

CISCO-PRODUCTS-MIB

IP-FORWARD-MIB

BGP-CISCO-BGP-MIBv2

 

SFP Support

Part Number

Specifications

SFP type

Temperature range1

Maximum distance

Cable type

Dom support

GLC-FE-100FX-RGD

100BASE-FX

FE

IND

2 km

Multimode fiber (MMF)

No

GLC-FE-100LX-RGD

100BASE-LX10

FE

IND

10 km

Single-mode fiber (SMF)

No

GLC-FE-100FX

100BASE-FX

FE

COM

2 km

MMF

No

GLC-FE-100LX

100BASE-LX10

FE

COM

10 km

SMF

No

GLC-FE-100EX

100BASE-EX

FE

COM

40 km

SMF

No

GLC-FE-100ZX

100BASE-ZX

FE

COM

80 km

SMF

No

GLC-FE-100BX-U

100BASE-BX10

FE

COM

10 km

SMF

No

GLC-FE-100BX-D

100BASE-BX10

FE

COM

10 km

SMF

No

GLC-SX-MM-RGD

1000BASE-SX

GE

IND

220-550 m

MMF

Yes

GLC-LX-SM-RGD

1000BASE-LX/LH

GE

IND

550 m/10 km

MMF/SMF

Yes

GLC-ZX-SM-RGD

1000BASE-ZX

GE

IND

70 km

SMF

Yes

SFP-GE-S

1000BASE-SX

GE

EXT

220-550 m

MMF

Yes

SFP-GE-L

1000BASE-LX/LH

GE

EXT

550 m/10 km

MMF/SMF

Yes

SFP-GE-Z

1000BASE-ZX

GE

EXT

70 km

SMF

Yes

GLC-BX-U

1000BASE-BX10

GE

COM

10 km

SMF

Yes

GLC-BX-D

1000BASE-BX10

GE

COM

10 km

SMF

Yes

GLC-SX-MM

1000BASE-SX

GE

COM

220-550 m

MMF

Yes

GLC-LH-SM

1000BASE-LX/LH

GE

COM

550 m/10 km

MMF/SMF

Yes

GLC-ZX-SM

1000BASE-ZX

GE

COM

70 km

SMF

Yes

GLC-EX-SMD

1000BASE-EX

GE

COM

40 km

SMF

Yes

GLC-TE

1000BASE-T

GE

EXT

100 m

Cat5e

No

GLC-BX40-U-I=

1000BASE-BX40

GE

IND

40km

SMF

Yes

GLC-BX40-D-I=

1000BASE-BX40

GE

IND

40km

SMF

Yes

GLC-BX40-DA-I=

1000BASE-BX40

GE

IND

40km

SMF

Yes

GLC-BX80-U-I=

1000BASE-BX80

GE

IND

80km

SMF

Yes

GLC-BX80-D-I=

1000BASE-BX80

GE

IND

80km

SMF

Yes

GLC-SX-MMD=

1000BASE-SX

GE

EXT

550m

MMF

Yes

GLC-LH-SMD=

1000BASE-LX/LH

GE

EXT

550m/10km

MMF/SMF

Yes

GLC-ZX-SMD=

1000BASE-ZX

GE

EXT

70km

SMF

Yes

GLC-T-RGD=

1000BASE-T

GE

IND

100m

Copper

NA

1 If non-industrial SFPs (EXT, COM) are used, the switch operating temperature must be derated.