Cisco Catalyst C9800-80-K9 Wireless Controller

36,805.52

Data Encryption

Power Supply

Modules

SmartNet

Сумма:

Add-ons total:

Всего:

Вес: 0 kg
скачать как CSV

Features

Maximum number of access points

Up to 6000

Maximum number of clients

64,000

Maximum throughput

Up to 80 Gbps

Maximum WLANs

4096

Maximum VLANs

4096

Maximum site tags

6000

Maximum Flex® APs per site

100

Maximum policy tags

6000

Maximum RF tags

6000

Maximum RF profiles

12000

Maximum policy profiles

1000

Maximum Flex profiles

6000

Fixed uplinks

8x 10G or 6x 10G 2x 1G SFP /SFP

Modular uplinks (optional)

The supported uplink modules are:

●  C9800-18X1GE(=)
●  C9800-10X10GE(=)
●  C9800-1X40GE(=)
●  C9800-2X40GE(=)
●  C9800-1X100GE(=)

The uplink modules are hot-swappable.

Supports 10G, 40G, and 100G QSFP transceivers

Redundant power supply

AC or DC power supply

Maximum power consumption with modules

600W

Deployment modes

Centralized, Cisco FlexConnect®, and Fabric Wireless (SD-Access)

Form factor

2RU

License

Smart License enabled

Operating system

Cisco IOS XE

Management

Cisco DNA Center, Cisco Prime® Infrastructure, integrated WebUI, and third party (open standards APIs)

Interoperability

AireOS-based controllers

Policy engine

Cisco Identity Services Engine (ISE)

Location platform

Cisco Connected Mobile Experiences (CMX)/Cisco DNA Spaces

Access points

Aironet 802.11ac Wave 1 and Wave 2 access points, Cisco Catalyst 9100 802.11ax access points

Physical dimensions

Width

17.3 inches (43.94 cm)

Depth

20.5 inches (52.07 cm)

Height

3.47 inches (8.81 cm)

Weight

31.5 lb (14.29 kg)

Ports and their purpose

1x RJ-45 console port

Console port for out-of-band management

1x USB 3.0 console port

Console port for out-of-band management

2x USB 3.0 ports

USB 3.0 ports for plugging in external memory

1x RJ-45 management port

Management port for out-of-band management. Also known as service port.

1x RJ-45 redundancy port

Redundancy port used for SSO

1x SFP Gigabit Ethernet redundancy port

●  Redundancy port used for SSO; works with Cisco supported SFPs (GLC-LH-SMD and GLC-SX-MMD) for RP port

Fixed uplink: 10G SFP /1G SFP ports

The ports are fixed uplinks, which can be used as 8x 10G SFP or 6x 10G plus 2x 1G

Modular uplink

The supported uplink modules are:

●  C9800-18X1GE(=)
●  C9800-10X10GE(=)
●  C9800-1X40GE(=)
●  C9800-2X40GE(=)
●  C9800-1X100GE(=)

The uplink modules are hot-swappable.

Supports 10G, 40G, and 100G QSFP transceivers

Front panel LEDs

LED

Color

Function

Power

PWR

Green

Green if all power rails are within spec

STATUS

SYS

Green

On: IOS has boot complete

Blinking: IOS boot in progress

Amber

On: System crash

Blinking: Secure boot failure

Off: ROMMON boot

ALARM

ALM

Green

On: ROMMON boot complete

Blinking: System upgrade in progress

Amber

On: ROMMON boot and SYSTEM bootup

Blinking: Temperature error and secure boot failure

HIGH AVAILABILITY

HA

Green

On: HA active

Blinking: HA standby hot

Amber

Slow blink: Booted with HA standby cold

Fast blink: HA maintenance

USB CON ENABLED

EN

Green

When LED is lit, USB console is enabled (RJ-45 console is disabled)

10/100/1000 RJ45 I/F

LINK

Green

Solid green indicates link

10/100/1000 RJ45 I/F

ACTIVITY

Green

Flashing green indicates activity

SSD Activity

SSD

Green

Indicates active use of the hard disk SSD memory devices in the unit

Power supply options

Power supply condition

Green (OK) LED status

Amber (Fail) LED status

No AC power to all power supplies

Off

Off

Power supply failure (includes over voltage, over current, over temperature, and fan failure)

Off

Red for power supply failure

Amber for fan failure

Power supply warning events in which the power supply continues to operate (high temperature, high power, and slow fan)

Off

1 Hz blinking

SFP support

Type

Modules supported

Small Form-Factor Pluggable (SFP)

GLC-BX-D

GLC-BX-U

GLC-LH-SMD

GLC-SX-MMD

GLC-ZX-SMD

GLC-TE

Enhanced SFP (SFP )

SFP-10G-SR

SFP-10G-SR-S

SFP-10G-SR-X

SFP-10G-LR

SFP-10G-LRM

SFP-10G-LR-X

SFP-10G-ER

SFP-10G-ZR

SFP-H10GB-ACU7M

SFP-H10GB-ACU10M

DWDM-SFP10G-30.33 — DWDM-SFP10G-61.41

Quad SFP (QSFP)

QSFP-40G-SR4

QSFP-40G-LR4

QSFP-40GE-LR4

QSFP-40G-ER4

QSFP-40G-SR4-S

QSFP-40G-LR4-S

QSFP-40G-SR-BD

QSFP-40G-BD-RX

QSFP-100G-SR4-S

QSFP-100G-LR4-S

Specifications

Wireless

IEEE 802.11a, 802.11b, 802.11g, 802.11d, WMM/802.11e, 802.11h, 802.11n, 802.11k, 802.11r, 802.11u, 802.11w, 802.11ac Wave 1 and Wave 2, 802.11ax

Wired, switching, and routing

IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX, 1000BASE-T, 1000BASE-SX, 1000-BASE-LH, IEEE 802.1Q VLAN tagging, IEEE 802.1AX Link Aggregation

Data standards

●  RFC 768 User Datagram Protocol (UDP)
●  RFC 791 IP
●  RFC 2460 IPv6
●  RFC 792 Internet Control Message Protocol (ICMP)
●  RFC 793 TCP
●  RFC 826 Address Resolution Protocol (ARP)
●  RFC 1122 Requirements for Internet Hosts
●  RFC 1519 Classless Interdomain Routing (CIDR)
●  RFC 1542 Bootstrap Protocol (BOOTP)
●  RFC 2131 Dynamic Host Configuration Protocol (DHCP)
●  RFC 5415 Control and Provisioning of Wireless Access Points (CAPWAP) Protocol
●  RFC 5416 CAPWAP Binding for 802.11

Security standards

●  Wi-Fi Protected Access (WPA)
●  IEEE 802.11i (WPA2, RSN)
●  Wi-Fi Protected Access 3 (WPA3)
●  RFC 1321 MD5 Message-Digest Algorithm
●  RFC 1851 Encapsulating Security Payload (ESP) Triple DES (3DES) Transform
●  RFC 2104 HMAC: Keyed-Hashing for Message Authentication
●  RFC 2246 TLS Protocol Version 1.0
●  RFC 2401 Security Architecture for the Internet Protocol
●  RFC 2403 HMAC-MD5-96 within ESP and AH
●  RFC 2404 HMAC-SHA-1-96 within ESP and AH
●  RFC 2405 ESP DES-CBC Cipher Algorithm with Explicit IV
●  RFC 2407 Interpretation for Internet Security Association Key Management Protocol (ISAKMP)
●  RFC 2408 ISAKMP
●  RFC 2409 Internet Key Exchange (IKE)
●  RFC 2451 ESP CBC-Mode Cipher Algorithms
●  RFC 3280 Internet X.509 Public Key Infrastructure (PKI) Certificate and Certificate Revocation List (CRL) Profile
●  RFC 4347 Datagram Transport Layer Security (DTLS)
●  RFC 5246 TLS Protocol Version 1.2

Encryption standards

●  Static Wired Equivalent Privacy (WEP) RC4 40, 104 and 128 bits
●  Advanced Encryption Standard (AES): Cipher Block Chaining (CBC), Counter with CBC-MAC (CCM), Counter with CBC Message Authentication Code Protocol (CCMP)
●  Data Encryption Standard (DES): DES-CBC, 3DES
●  Secure Sockets Layer (SSL) and Transport Layer Security (TLS): RC4 128-bit and RSA 1024- and 2048-bit
●  DTLS: AES-CBC
●  IPsec: DES-CBC, 3DES, AES-CBC
●  802.1AE MACsec encryption

Authentication, Authorization, and Accounting (AAA)

●  IEEE 802.1X
●  RFC 2548 Microsoft Vendor-Specific RADIUS Attributes
●  RFC 2716 Point-to-Point Protocol (PPP) Extensible Authentication Protocol (EAP)-TLS
●  RFC 2865 RADIUS Authentication
●  RFC 2866 RADIUS Accounting
●  RFC 2867 RADIUS Tunnel Accounting
●  RFC 2869 RADIUS Extensions
●  RFC 3576 Dynamic Authorization Extensions to RADIUS
●  RFC 5176 Dynamic Authorization Extensions to RADIUS
●  RFC 3579 RADIUS Support for EAP
●  RFC 3580 IEEE 802.1X RADIUS Guidelines
●  RFC 3748 Extensible Authentication Protocol (EAP)
●  Web-based authentication
●  TACACS support for management users

Management standards

●  Simple Network Management Protocol (SNMP) v1, v2c, v3
●  RFC 854 Telnet
●  RFC 1155 Management Information for TCP/IP-based Internets
●  RFC 1156 MIB
●  RFC 1157 SNMP
●  RFC 1213 SNMP MIB II
●  RFC 1350 Trivial File Transfer Protocol (TFTP)
●  RFC 1643 Ethernet MIB
●  RFC 2030 Simple Network Time Protocol (SNTP)
●  RFC 2616 HTTP
●  RFC 2665 Ethernet-Like Interface Types MIB
●  RFC 2674 Definitions of Managed Objects for Bridges with Traffic Classes, Multicast Filtering, and Virtual Extensions
●  RFC 2819 Remote Monitoring (RMON) MIB
●  RFC 2863 Interfaces Group MIB
●  RFC 3164 Syslog
●  RFC 3414 User-Based Security Model (USM) for SNMPv3
●  RFC 3418 MIB for SNMP
●  RFC 3636 Definitions of Managed Objects for IEEE 802.3 MAUs
●  RFC 4741 Base NETCONF protocol
●  RFC 4742 NETCONF over SSH
●  RFC 6241 NETCONF
●  RFC 6242 NETCONF over SSH
●  RFC 5277 NETCONF event notifications
●  RFC 5717 Partial Lock Remote Procedure Call
●  RFC 6243 With-Defaults capability for NETCONF
●  RFC 6020 YANG
●  Cisco private MIBs

Management interfaces

●  Web-based: HTTP/HTTPS
●  Command-line interface: Telnet, Secure Shell (SSH) Protocol, serial port
●  SNMP
●  NETCONF

Hard Disk Drives (HDD)

●  SATA Solid-State Drive (SSD)
●  240 GB of memory

Environmental conditions supported

Operating temperature:

●  Normal: 0° to 40° C (32° to 104°F)
●  Short term:0° to 50° C (32° to 122°F)

Nonoperating temperature:

●  -40° to 65° C (-104° to 149°F)

Operating humidity:

●  Normal: 10% to 90% noncondensing
●  Short term: 5% to 90% noncondensing

Nonoperating temperature humidity:

●  5% to 93% at 82°F (28°C)

Operating altitude:

●  Appliance operating: 0 to 3000 m (0 to 10,000 ft)
●  Appliance nonoperating: 0 to 12,192 m (0 to 40,000 ft)

Electrical input:

●  AC input frequency range: 47 to 63 Hz
●  AC input range: 90 to 264 VAC with AC PEM
●  DC input range: -40 to -72 VDC with DC PEM

Maximum power with modules: 600W

Heat dissipation: 2047 BTU/hr

Sound power level measure:

●  A-weighted sound power level is 70.5 LpAm (dBA) @ 27C nominal operation

Regulatory compliance

Safety:

●  UL/CSA 60950-1
●  IEC/EN 60950-1
●  AS/NZS 60950.1
●  CAN/CSA-C22.2 No. 60950-1

EMC – Emissions:

●  FCC 47CFR15
●  AS/NZS CISPR 22
●  CISPR 22
●  EN55022/EN55032 (EMI-1)
●  ICES-003
●  VCCI
●  KN 32 (EMI-2)
●  CNS-13438

Class A

EMC – Emissions:

●  EN61000-3-2 Power Line Harmonics (EMI-3)
●  EN61000-3-3 Voltage Changes, Fluctuations, and Flicker (EMI-3)

EMC – Immunity:

●  IEC/EN61000-4-2 Electrostatic Discharge Immunity
●  IEC/EN61000-4-3 Radiated Immunity
●  IEC/EN61000-4-4 EFT-B Immunity (AC Power Leads)
●  IEC/EN61000-4-4 EFT-B Immunity (DC Power Leads)
●  IEC/EN61000-4-4 EFT-B Immunity (Signal Leads)
●  IEC/EN61000-4-5 Surge AC Port
●  IEC/EN61000-4-5 Surge DC Port
●  IEC/EN61000-4-5 Surge Signal Port
●  IEC/EN61000-4-6 Immunity to Conducted Disturbances
●  IEC/EN61000-4-8 Power Frequency Magnetic Field Immunity
●  IEC/EN61000-4-11 Voltage Dips, Short Interruptions, and Voltage Variations
●  K35 (EMI-2)

EMC (ETSI/EN)

●  EN 300 386 Telecommunications Network Equipment (EMC) (EMC-3)
●  EN55022 Information Technology Equipment (Emissions)
●  EN55024/CISPR 24 Information Technology Equipment (Immunity)
●  EN50082-1/EN61000-6-1 Generic Immunity Standard (EMC-4)