C9300-24T-A Catalyst 9300 24-port modular uplinks data only, Network Advantage
€2,168.99
Platform details |
|
FRU Power Supply |
FRU Fans |
Modular Uplinks |
Stacking Bandwidth Support |
Cisco StackPower |
Catalyst 9800 Embedded WLC |
SD-Access Support |
|
✓ |
✓ |
✓ |
480 Gbps |
✓ (StackPower) |
Yes (200 APs) |
Yes (256 Virtual Networks) |
|
Configurations
Total 10/100/1000, Multigigabit copper or SFP Fiber |
Uplink Configuration |
Default AC power supply |
|
24 Data |
Modular Uplinks |
350W AC |
Power supply
Default power supply |
Available PoE power |
With 350W Secondary PS |
With 715W Secondary PS |
With 1100W Secondary PS |
|
PWR-C1-350WAC*** |
n/a |
n/a |
n/a |
n/a |
Supported stacking options
Stacking support |
Stacking bandwidth support |
Optional Stacking hardware |
Number of members |
Supported stack members |
|
StackWise®-480 |
480 Gbps |
StackWise Cable |
8 |
Other C9300 SKUs with same license level C9300 higher scale SKUs only stack with other like higher scale models |
|
Performance specifications
Total number of MAC addresses |
32,000 |
|||
Total number of IPv4 routes (ARP plus learned routes) |
32,000 (24,000 direct routes and 8000 indirect routes) |
|||
IPv6 routing entries |
16,000 |
|||
Multicast routing scale |
8,000 |
|||
QoS scale entries |
5,120 |
|||
ACL scale entries |
5,120 |
|||
Packet buffer per SKU |
16 MB buffer for 24- or 48-port Gigabit Ethernet models 32 MB buffer for 24 and 48-port Multigigabit |
|||
FNF entries |
64,000 flow on 24- and 48-port Gigabit Ethernet models 128,000 flows on 24-port Multigigabit |
|||
DRAM |
8 GB |
|||
Flash |
16 GB |
|||
VLAN IDs |
4094 |
|||
Total Switched Virtual Interfaces (SVIs) |
1000 |
|||
Jumbo frames |
9198 bytes |
|||
Total routed ports per Catalyst 9300 Series stack |
448 |
Bandwidth specifications
Switching capacity |
Switching capacity with stacking |
Forwarding rate |
Forwarding rate with stacking |
|
208 Gbps |
688 Gbps |
154.76 Mpps |
511.90 Mpps |
Dimensions, Weight, and Mean Time between failures metrics
General Specifications |
|||
Dimensions (H x W x D) inches |
|||
Chassis only |
W/ Default Power Supply |
W/ 1100W Power Supply |
|
1.73 x 17.5 x 16.1 |
1.73 x 17.5 x 17.7 |
1.73 x 17.5 x 19.2 |
Dimensions (H x W x D) Cms |
|||
|
4.4 x 44.5 x 40.9 |
4.4 x 44.5 x 44.9 |
4.4 x 44.5 x 48.8 |
Weight (with default power supply) |
|||
Pounds |
Kilograms |
||
16.03 |
7.27 |
PWR-C1-350WAC-P |
1,335,012 (ranges from 1.3M to 3.1M depending on temperature, input voltage and vendor) |
314,790 |
Environmental ranges
Acoustic noise Measured per ISO 7779 and declared per ISO 9296 Bystander positions operating to an ambient temperature of 25°C |
With AC power supply (with 24 PoE ports loaded for C9300 SKUs) ● LpA: 45dB typical, 48 dB max
● LwA: 5.6B typical, 5.9B max
With AC power supply (with half the number of PoE ports loaded for C9300L SKUs) ● LpA: 44dB typical, 47 dB max
● LwA: 5.5B typical, 5.8B max
Typical: Noise emission for a typical configuration Maximum: Statistical maximum to account for variation in production |
Connectors
Connectors and cabling |
● 1000BASE-T ports: RJ-45 connectors, 4-pair Cat 5E UTP cabling
● Multigigabit-T ports: RJ-45 connectors, 4-pair Cat 5E, Cat 6, Cat 6A UTP cabling
● 1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Cat 5E UTP cabling
● SFP transceivers: LC fiber connectors (single-mode or multimode fiber)
● SFP transceivers: LC fiber connectors (single-mode or multimode fiber)
● QSFP transceivers: MPO and LC fiber connectors (single-mode or multimode fiber)
● QSFP connector
● SFP connector
● Cisco StackWise stacking ports: copper-based Cisco StackWise cabling
● Cisco StackPower: Cisco proprietary power stacking cables
● Ethernet management port: RJ-45 connectors, 4-pair Cat 5 UTP cabling
● Management console port: RJ-45-to-DB9 cable for PC connections
|
● Customers can provide power to a switch by using the internal power at the back of the switch
● Internal power supply connector: The internal power supply is an auto-ranging unit. It supports input voltages between 100 (115 for 1100WAC) and 240 VAC. Use the supplied AC power cord to connect the AC power connector to an AC power outlet
|
Management and standards support*
Description |
Specification |
|
Management |
BRIDGE-MIB CISCO-BRIDGE-EXT-MIB CISCO-BULK-FILE-MIB CISCO-CABLE-DIAG-MIB CISCO-CALLHOME-MIB CISCO-CEF-MIB CISCO-CIRCUIT-INTERFACE-MIB CISCO-CONFIG-COPY-MIB CISCO-CONFIG-MAN-MIB CISCO-DEVICE-LOCATION-MIB CISCO-DHCP-SNOOPING-MIB CISCO-EIGRP-MIB CISCO-EMBEDDED-EVENT-MGR-MIB CISCO-ENTITY-FRU-CONTROL-MIB CISCO-ENTITY-SENSOR-MIB CISCO-ENTITY-VENDORTYPE-OID-MIB CISCO-ERR-DISABLE-MIB CISCO-FLASH-MIB CISCO-FLOW-MONITOR-MIB CISCO-FTP-CLIENT-MIB CISCO-HSRP-EXT-MIB CISCO-HSRP-MIB CISCO-IETF-BFD-MIB CISCO-IETF-PPVPN-MPLS-VPN-MIB CISCO-IETF-PW-MPLS-MIB CISCO-IF-EXTENSION-MIB CISCO-IGMP-FILTER-MIB CISCO-IMAGE-LICENSE-MGMT-MIB CISCO-IMAGE-MIB CISCO-IP-CBR-METRICS-MIB CISCO-IP-STAT-MIB CISCO-IP-TAP-MIB CISCO-IP-URPF-MIB CISCO-IPSEC-FLOW-MONITOR-MIB CISCO-IPSEC-MIB CISCO-IPSEC-PROVISIONING-MIB CISCO-IPSLA-AUTOMEASURE-MIB CISCO-IPSLA-ECHO-MIB CISCO-IPSLA-JITTER-MIB CISCO-L2-CONTROL-MIB CISCO-L2L3-INTERFACE-CONFIG-MIB CISCO-LAG-MIB CISCO-LICENSE-MGMT-MIB CISCO-LOCAL-AUTH-USER-MIB CISCO-MAC-NOTIFICATION-MIB CISCO-MDI-METRICS-MIB CISCO-MEDIA-METRICS-MIB CISCO-MEMORY-POOL-MIB CISCO-MPLS-LSR-EXT-STD-MIB CISCO-NBAR-PROTOCOL-DISCOVERY-MIB CISCO-NHRP-EXT-MIB CISCO-NTP-MIB CISCO-PAGP-MIB CISCO-PORT-SECURITY-MIB |
CISCO-PORT-STORM-CONTROL-MIB CISCO-POWER-ETHERNET-EXT-MIB CISCO-PRIVATE-VLAN-MIB CISCO-PROCESS-MIB CISCO-PRODUCTS-MIB CISCO-RF-MIB CISCO-RTP-METRICS-MIB CISCO-RTTMON-ICMP-MIB CISCO-STACKWISE-MIB CISCO-STP-EXTENSIONS-MIB CISCO-SYSLOG-MIB CISCO-TCP-MIB CISCO-UDLDP-MIB CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB ENTITY-MIB HC-ALARM-MIB HC-RMON-MIB IEEE8023-LAG-MIB IF-MIB IP-FORWARD-MIB IP-MIB LLDP-EXT-MED-MIB LLDP-MIB MAU-MIB MPLS-L3VPN-STD-MIB MPLS-LSR-STD-MIB MPLS-VPN-MIB OLD-CISCO-CHASSIS-MIB OLD-CISCO-CPU-MIB OLD-CISCO-INTERFACES-MIB OLD-CISCO-IP-MIB OLD-CISCO-MEMORY-MIB OLD-CISCO-SYS-MIB OLD-CISCO-TCP-MIB OLD-CISCO-TS-MIB POWER-ETHERNET-MIB RFC1213-MIB RMON-MIB RMON2-MIB SMON-MIB SNMPv2-MIB SONET-MIB TCP-MIB |
Standards |
IEEE 802.1s IEEE 802.1w IEEE 802.1x IEEE 802.1x-Rev IEEE 802.3ad IEEE 802.3ae IEEE 802.3af IEEE 802.3at IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports IEEE 802.1D Spanning Tree Protocol IEEE 802.1p CoS prioritization IEEE 802.1Q VLAN IEEE 802.3 10BASE-T specification IEEE 802.3u 100BASE-TX specification IEEE 802.3ab 1000BASE-T specification IEEE 802.3z 1000BASE-X specification IEEE 802.3bz Multirate 2.5G/5G specification IEEE 802.3an 10G BASE-T specification |
RMON I and II standards SNMPv1, v2c, and v3 |
Power specifications
Power supply rated maximum |
350W |
|||
Total output BTU (note: 1000 BTU/hr = 293W) |
1207 BTU/hr, 350W |
|||
Input-voltage range and frequency |
100 to 240 VAC, 50 to 60 Hz |
|||
Input current |
4-2A |
|||
Output ratings |
-56V at 6.25A |
|||
Output holdup time |
16.7 ms minimum at 100VAC |
|||
Power-supply input receptacles |
IEC 320-C14 (IEC60320-C14) |
|||
Power cord rating |
10A |
|||
Physical specifications |
(H x W x D): 1.58 x 3.25 x 12.20 in Weight: 2.3 lb (1.2 kg) |
Power specifications – platinum rated power supplies
Power supply rated maximum output power |
350W |
||||
Total output BTU |
1194 BTU/hr, 350W |
||||
Input-voltage range and frequency |
100 to 240 VAC, 50 to 60 Hz |
||||
Input current |
4-2A |
||||
Output ratings |
-56V at 6.25A |
||||
Output holdup time |
20 ms minimum at 100VAC |
||||
Power-supply input receptacles |
IEC 320-C14 (IEC60320-C14) |
||||
Power cord rating |
10A |
||||
Physical specifications |
(H x W x D): 1.58 x 3.25 x 12.20 in Weight: 2.3 lb (1.2 kg) |
||||
Operating temperature |
Normal operating temperature* and altitudes: ● -5°C to 45°C, up to 5000 feet (1500m)
● -5°C to 40°C, up to 10,000 feet (3000m)
*Minimum ambient temperature for cold start is 32°F (0°C) Short-term* exceptional conditions: ● -5°C to 50°C, up to 5000 feet (1500m)
● -5°C to 45°C, up to 10,000 feet (3000m)
● -5°C to 45°C, at sea level with single fan failure
*Not more than following in one-year period: 96 consecutive hours, or 360 hours total, or 15 occurrences |
||||
Storage temperature |
-40° to 158°F (-40° to 70°C) |
||||
Relative humidity operating and nonoperating noncondensing |
5% to 90% noncondensing |
||||
Altitude |
10,000 ft. (3000 meters), up to 45°C |
||||
EMI and EMC compliance |
FCC Part 15 (CFR 47) Class A ICES-003 Class A EN 55032 Class A CISPR 32 Class A AS/NZS 3548 Class A BSMI Class A (AC input models only) VCCI Class A EN 55024, EN300386, EN 61000-3-2, EN 61000-3-3 EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN 61000-6-1 |
||||
Safety compliance |
|||||
LED indicators |
“AC OK”: Input power to the power supply is OK “PS OK”: Output power from the power supply is OK |
Safety and compliance information
Safety certifications |
● UL 60950-1
● CAN/CSA-C222.2 No. 60950-1
● EN 60950-1
● IEC 60950-1
● AS/NZS 60950.1
● IEEE 802.3
|
Electromagnetic emissions certifications |
● 47 CFR Part 15
● CISPR22 Class A
● EN 300 386 V1.6.1
● EN 55022 Class A
● EN 55032 Class A
● CISPR 32 Class A
● EN61000-3-2
● EN61000-3-3
● ICES-003 Class A
● TCVN 7189 Class A
● V-3 Class A
● CISPR24
● EN 300 386
● EN55024
● TCVN 7317
● V-2/2015.04
● V-3/2015.04
● CNS13438
● KN32
● KN35
● IEC 61000-6-1
● EN 61000-6-1
⠀
Additional Certifications for C9300L SKUs: ● QCVN 118:2018/BTTTT
● CISPR24/25
● CISPR 32 Class A
● VCCI-CISPR 32 Class A
● EN55035
|
Environmental |
Reduction of Hazardous Substances (ROHS) 5 |