C8500-12X Cisco Catalyst 8500 Series Edge Platform

3,315,019.10

Memory

M2 Storage

SSD Storage

Power Supply

Rack Mount Accessory Kit

Optics for Integrated ports

SmartNet

Сумма:

Add-ons total:

Всего:

Вес: 0 kg
скачать как CSV

Features

All-new third-generation Quantum Flow Processor (QFP) ASIC

●  Inline hardware-accelerated encryption for high-throughput IPsec and MACsec
●  High-performance routing and SD-WAN with services

IPsec

●  Up to 2.5X higher IPsec throughput than 2nd Gen QFP devices

Multicore control processor

●  Intel x86 CPU with 16 GB memory default (up to 64 GB memory) for high-speed control plane processes

Interface flexibility

●  Options for 1GE, 10GE, 40GE, and 100GE ports

DRAM

●  All Catalyst 8500 Edge Platforms have 16 GB default DRAM and can be upgraded to 32 GB and 64 GB for higher scale

SSD storage

●  Default 32-GB eUSB for storage with optional 480-GB SSD upgrade for additional storage on the platform

Redundancy

●  High-efficiency dual power supplies by default for power supply redundancy
●  All Catalyst 8500 Edge Platforms support software redundancy with 2 Cisco IOS processes running on a single device (IOS XE routing mode)

Form factor

●  Compact 1RU form factor

Integrated security

●  Hardware-anchored Secure Boot and Secure Unique Device Identification (SUDI) support for Plug and Play to verify the identity of the hardware and software

 

Configurations

Description

Max 1GE ports

Max 10GE ports

Max 40GE ports

Max 100GE ports

12-port 1/10GE

12

12

0

0

 

Cisco controller mode (SD-WAN) performance specifications

C8500-12X

SD-WAN IPsec Throughput (1400Bytes, clear text)

Up to 51Gbps

SD-WAN IPsec Throughput (IMIX*, clear text**)

Up to 22.6Gbps

SD-WAN Overlay Tunnels scale

8000

 

Cisco autonomous mode (non SD-WAN) performance specifications

C8500-12X

IPv4 Forwarding Throughput (1400Bytes)

Up to 118Gbps

IPsec Throughput (1400Bytes, clear text**)

Up to 84Gbps

Number of IPsec SVTI Tunnels

4000

 

Cisco autonomous mode (non SD-WAN) system scalability

C8500-12X

Number of ACLs per system

4000

Number of IPv4 ACEs per system

47K

Number of IPv4 Routes

4M w/ default 16GB

Number of IPv6 Routes

4M w/ default 16GB

Number of Queues

256K

Number of NAT Sessions

12M

Number of Firewall Sessions

6M

Number of VRFs

8000

*IMIX is average packet size of 352 Bytes packet size
**Based on clear text traffic measurement from traffic generator

Power supplies

Power supply feature

PWR-CH1-750WACR

PWR-CH1-950WDCR

Power maximum rating

750W

950W

Input-voltage range and frequency

85 to 264 VAC

47 to 63 Hz

DC: -40 to -72V; -48V nominal

Power supply efficiency

80 Plus Platinum

86%

Input current

9.4 A to 3.0 A

27.6 A to 15.3 A (23 A)

Output ratings

12 V 63 A

12 V 79 A

Output holdup time

20 ms

4 ms

Power supply input receptacles

IEC 320 C14

Amphenol FXTH series 2 terminal block

Power cord rating

10 A

#10 wire 30 A

 

Software features and protocols for autonomous mode

Protocols

IPv4, IPv6, static routes, Routing Information Protocol Versions 1 and 2 (RIP and RIPv2), Open Shortest Path First (OSPF), Enhanced Interior Gateway Routing Protocol (EIGRP), Border Gateway Protocol (BGP), BGP Router Reflector, Intermediate System-to-Intermediate System (IS-IS), Multicast Internet Group Management Protocol Version 3 (IGMPv3), Protocol Independent Multicast Sparse Mode (PIM SM), PIM Source-Specific Multicast (SSM), Resource Reservation Protocol (RSVP), Cisco Discovery Protocol, Encapsulated Remote Switched Port Analyzer (ERSPAN), Cisco IOS IP Service-Level Agreements (IPSLA), Call Home, Cisco IOS Embedded Event Manager (EEM), Internet Key Exchange (IKE), Access Control Lists (ACL), Ethernet Virtual Connections (EVC), Dynamic Host Configuration Protocol (DHCP), Frame Relay, DNS, Locator ID Separation Protocol (LISP), Hot Standby Router Protocol (HSRP), RADIUS, Authentication, Authorization, and Accounting (AAA), Application Visibility and Control (AVC), Distance Vector Multicast Routing Protocol (DVMRP), IPv4-to-IPv6 Multicast, Multiprotocol Label Switching (MPLS), Layer 2 and Layer 3 VPN, IPsec, MACsec Layer 2 Tunneling Protocol Version 3 (L2TPv3), Bidirectional Forwarding Detection (BFD), IEEE 802.1ag, and IEEE 802.3ah

High Availability

Software redundancy with dual IOS, Box-to-Box application-level redundancy

Encapsulations

Generic Routing Encapsulation (GRE), Ethernet, 802.1q VLAN, Point-to-Point Protocol (PPP), Multilink Point-to-Point Protocol (MLPPP), High-Level Data Link Control (HDLC), and PPP over Ethernet (PPPoE)

Traffic management

Quality of Service (QoS), Class-Based Weighted Fair Queuing (CBWFQ), Weighted Random Early Detection (WRED), Hierarchical QoS, Policy-Based Routing (PBR), Performance Routing (PfR), and Network-Based Application Recognition (NBAR)

Cryptographic algorithms

Encryption: DES, 3DES, AES-128, or AES-256 (in CBC and GCM modes)

Authentication: RSA (748/1024/2048 bit), ECDSA (256/384 bit)

Integrity: MD5, SHA, SHA-256, SHA-384, SHA-512

 

Software features and protocols for controller mode

Core Features

IPv4, IPv6, static routes, Open Shortest Path First (OSPF), Enhanced Interior Gateway Routing Protocol (EIGRP), Border Gateway Protocol (BGP), Overlay Management Protocol (OMP), Application Aware Routing (AAR), Traffic Engineering, Service Insertion, zero-trust, whitelisting, tamper-proof module, DTLS/TLS, IPsec, classification, prioritization, low latency queuing, remarking, shaping, scheduling, policing, mirroring, Multicast IPv4 Support, Service advertisement and insertion policy, SNMP, NTP, DNS client, Dynamic Host Configuration Protocol (DHCP), DHCP client, DHCP server, DHCP relay, config archival, syslog, SSH, SCP, Cflowd v10 IPFIX export, IPv6 for transport-side, VRRP, MPLS, NAT (DIA, Service-side, static, overload/PAT, NAT64, etc), NAT pools, split DNS, Access Control Lists (ACL), Bidirectional Forwarding Detection (BFD), Netconf over SSH, CLI, NTP server support, BFD with service-side BGP, BGP community propagation to OMP, 6 SLA classes for AAR, Trustsec/SDA (Inline SGT propagation), custom app with SD-AVC, multicast AAR, dynamic on-demand tunnels, PIM-SM, OSPFv3, route policies, Multi-VRF support

Encapsulations

Generic Routing Encapsulation (GRE), Ethernet, 802.1q VLAN

Application Experience

Quality of Service (QoS), Forward Error Correction (FEC), COS Marking, Weighted Random Early Detection (WRED), Hierarchical QoS, Policy-Based Routing (PBR), Network-Based Application Recognition (NBAR), Software Defined Application Visibility and Control (SD-AVC), per tunnel QoS, Cloud onRamp for SaaS, Enhanced Office 365 traffic steering, Direct Internet Access, Flexible Netflow (FnF)

Cryptographic Algorithms

Encryption: AES-256 (in CBC and GCM modes), Internet Key Exchange (IKE), Cisco PKI

Authentication: AAA, RSA (2048 bit), ESP-256-CBC, HMAC-SHA1, ECDSA (256/384 bit)

Integrity: SHA-1, SHA-2

Security

Built-in end-to-end Segmentation (VPNs), ZBFW, PKI, DNS Layer Security, Security Internet Gateway (Umbrella, Zscaler), ALG for ZBFW

 

Mechanical specifications

Part number

C8500-12X

Dimensions (H x W x D)

1.73 in. x 17.50 in. x 18.46 in.

Rack Units (RU)

1RU

Chassis weight with 2x AC power supplies and fan tray

20.25 lbs

Input voltage

AC: 85 to 264 VAC

DC: -40 to 72V; 48V nominal

Operating temperature

32 to 104°F

(0 to 40°C)

Storage temperature

-40 to 150°F

(-40 to 70°C)

Relative humidity operating and nonoperating noncondensing

Ambient (noncondensing) operating: 10 to 85%

Ambient (noncondensing) nonoperating and storage: 5 to 95%

NEBS criteria levels

GR-1089 and GR-63

Altitude

-500 to 10,000 feet

(152 to 3048 meters)

Mean Time Between Failures (MTBF)

156,200 hours

 

Safety and compliance

Safety certifications

●  UL 60950-1
●  CAN/CSA-C22.2 No. 60950-1
●  EN 60950-1
●  IEC 60950-1
●  AS/NZS 60950-1
●  GB4943

EMC (Emissions)

47 CFR Part 15 Class A

ICES 003 Class A

AS/NZS CISPR 32 Class A

CISPR 22/CISPR 32 Class A

EN55022/EN55032 Class A

VCCI Class A

CNS-13438 Class A

KN32 Class A

IEC/EN 61000-3-2: Power Line Harmonics

IEC/EN 61000-3-3: Voltage Fluctuations and Flicker

EMC (Immunity)

IEC/EN-61000-4-2: Electrostatic Discharge Immunity

IEC/EN-61000-4-3: Radiated Immunity

IEC/EN-61000-4-4: Electrical Fast Transient Immunity

IEC/EN-61000-4-5: Surge AC, DC, and Signal Ports

IEC/EN-61000-4-6: Immunity to Conducted Disturbances

IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations

KN35

EMC (ETSI/EN)

EN300 386: Telecommunications Network Equipment (EMC)

EN55022: Information Technology Equipment (Emissions)

EN55032: Multimedia Equipment (Emissions)

EN55024: Information Technology Equipment (Immunity)

EN55035: Multimedia Equipment (Immunity)

EN50082-1/EN-61000-6-1: Generic Immunity Standard