C1000-48FP-4G-L Catalyst 1000 48port GE, Full POE, 4x1G SFP
7,447.00$
Specifications |
Gigabit Ethernet / FE ports |
Uplink interfaces |
PoE power budget |
Fanless |
Dimensions (WxDxH in inches) |
Weight (kg) |
48 10/100/1000 RJ45 PoE |
4 SFP |
740W |
N |
17.48 x 13.78 x 1.73 |
5.82 |
Console ports |
|||||||||
RJ-45 Ethernet |
1 |
||||||||
USB mini-B |
1 |
||||||||
USB-A port for storage and Bluetooth console |
1 |
||||||||
Memory and processor |
|||||||||
CPU |
ARM v7 800 MHz |
||||||||
DRAM |
512 MB |
||||||||
Flash memory |
256 MB |
||||||||
Performance |
|||||||||
FE: 8.8 Gbps 1G: 52 Gbps 10G: 88Gpbs |
|||||||||
Switching bandwidth |
FE: 17.6 Gbps 1G: 104 Gbps 10G: 176 Gbps |
||||||||
Forwarding rate |
FE: 13.09 Mpps 1G: 77.38 Mpps 10G: 130.94 |
||||||||
MAC addresses |
16000 |
||||||||
IPv4 unicast direct routes |
542 |
||||||||
IPv4 unicast indirect routes |
256 |
||||||||
IPv6 unicast direct routes |
414 |
||||||||
IPv6 unicast indirect routes |
128 |
||||||||
IPv4 multicast routes and IGMP groups |
1024 |
||||||||
IPv6 multicast groups |
1024 |
||||||||
IPv4/MAC security ACEs |
600 (FE: 384) |
||||||||
IPv6 security ACEs |
600 (FE: 256) |
||||||||
Maximum active VLANs |
256 |
||||||||
VLAN IDs available |
4094 |
||||||||
Maximum STP instances |
64 |
||||||||
Maximum SPAN sessions |
4 |
||||||||
MTU-L3 packet |
9198 bytes |
||||||||
Jumbo Ethernet frame |
10,240 bytes |
||||||||
Dying Gasp |
Yes (FE: No) |
||||||||
MTBF in hours (data) |
1,452,667 |
||||||||
MTBF in hours (PoE) |
856,329 |
||||||||
MTBF in hours (Full PoE) |
856,329 |
Environmental |
|||||||||
Operating temperature |
|||||||||
Sea level |
-5 to 50 deg C* |
||||||||
Up to 5,000ft (1500 m) |
-5 to 45 deg C |
||||||||
Upto 10,000 (3000 m) |
-5 to 40 deg C |
||||||||
Operating altitude |
10,000 ft (3,000m) |
||||||||
Operating relative humidity |
5% to 90% at 40 deg C (non-condensing) |
||||||||
Storage temperature |
-13 to 158F (-25 to 70C) |
||||||||
Storage altitude |
15,000 ft (4500m) |
||||||||
Storage relative humidit |
5% to 95% at 65 deg C (non-condensing) |
||||||||
*Note: |
● 50C operation is supported for short term operation only;
● When using C1000-8T-E-2G-L, C1000-8T-2G-L, C1000-8P-E-2G-L, C1000-8P-2G-L, C1000-8FP-E-2G-L, C1000-8FP-2G-L, C1000-16T-E-2G-L, C1000-16T-2G-L, C1000-16P-E-2G-L, C1000-16P-2G-L, C1000-16FP-2G-L, C1000-24T-4G-L, C1000-24P-4G-L with GLC-BX-U or GLC-BX-D SFP module, the thermal limitations are as follows:
◦ Up to 5,000 feet, the operation temperature should not exceed 45ºC. ◦ Up to 10,000 feet, the operation temperature should not exceed 40ºC. ● When using C1000-24T-4X-L, C1000-24P-4X-L with SFP-10G-ER or SFP-10G-ER-S SFP module, the thermal limitations are as follows:
◦ Up to 5,000 feet, the operation temperature should not exceed 45ºC. ◦ Up to 10,000 feet, the operation temperature should not exceed 40ºC. ● Minimum ambient temperature for cold start is at 0 deg C (32 deg F)
|
||||||||
Electrical |
Data |
FE Data |
|||||||
Voltage (auto ranging) |
110 to 220V AC in |
||||||||
Frequency |
50 to 60 Hz |
||||||||
Current |
0.29A to 0.48A |
0.24A to 0.69A |
|||||||
Power rating |
0.09 kVA |
0.035 kVA |
|||||||
Electrical |
PoE |
FE PoE |
|||||||
Voltage (auto ranging) |
110 to 220V AC in |
||||||||
Frequency |
50 to 60 Hz |
||||||||
Current |
0.37A to 0.64A |
0.26A to 0.46A |
|||||||
Power rating |
0.48 kVA |
0.046 kVA |
|||||||
Electrical |
Full PoE |
||||||||
Voltage (auto ranging) |
110 to 220V AC in |
||||||||
Frequency |
50 to 60 Hz |
||||||||
Current |
0.45A to 0.94A |
||||||||
Power rating |
0.95 kVA |
||||||||
Data |
FE Data |
||||||||
0% traffic |
1G: 27.37 |
21.41 |
|||||||
10G: 29.4 |
|
||||||||
10% traffic |
1G: 41.57 |
23.02 |
|||||||
10G: 42.28 |
|
||||||||
100% traffic |
1G: 53.66 |
23.03 |
|||||||
10G: 54.73 |
|
||||||||
Weighted average |
1G: 40.87 |
22.49 |
|||||||
10G: 42.1 |
|
||||||||
Power consumption (watts) |
PoE |
FE PoE |
|||||||
|
|
|
|||||||
0% traffic |
1G: 27.9 |
21.62 |
|||||||
10G: 28.0 |
|
||||||||
10% traffic |
1G: 42.77 |
24.74 |
|||||||
10G: 42.73 |
|
||||||||
100% traffic |
1G: 54.25 |
24.75 |
|||||||
10G: 54.49 |
|
||||||||
Weighted average |
1G: 41.64 |
23.70 |
|||||||
10G: 41.74 |
|
||||||||
Power consumption (watts) |
Full PoE |
||||||||
0% traffic |
1G: 30.61 |
||||||||
10G: 30.91 |
|||||||||
10% traffic |
1G: 45.16 |
||||||||
10G: 45.78 |
|||||||||
100% traffic |
1G: 61.66 |
||||||||
10G: 62.26 |
|||||||||
Weighted average |
1G: 45.81 |
||||||||
10G: 46.31 |
|||||||||
|
Note: The wattage rating on the power supply does not represent actual power draw. It indicates the maximum power draw possible by the power supply. This rating can be used for facility capacity planning. For PoE switches, cooling requirements are smaller than total power draw because a significant portion of the load is dissipated in the endpoints. |
Acoustic noise |
|
Sound pressure (Typical) |
C1000-48FP-4G-L C1000-48FP-4X-L – 47.6dB |
Note: Bystander positions operating mode at 77°F (25°C) ambient; All other models are fanless for silent operations |
Safety and compliance |
|||||||||
Safety |
UL 60950-1 Second Edition, CAN/CSA-C22.2 No. 60950-1 Second Edition, EN 60950-1 Second Edition, IEC 60950-1 Second Edition, AS/NZS 60950-1, IEC 62368-1, UL 62368-1 GB 4943.1-2011 |
||||||||
EMC: Emissions |
47CFR Part 15 Class A, AS/NZS CISPR32 Class A, CISPR32 Class A, EN55032 Class A, ICES-003 Class A, VCCI-CISPR32 Class A, EN61000-3-2, EN61000-3-3, KN32 Class A, CNS13438 Class A |
||||||||
EMC: Immunity |
EN55024 (including EN 61000-4-5), EN300386, KN35 |
||||||||
Environmental |
Reduction of Hazardous Substances (RoHS) including Directive 2011/65/EU |
||||||||
Telco |
Common Language Equipment Identifier (CLEI) code |
||||||||
U.S. government certifications |
USGv6 and IPv6 Ready Logo |
||||||||
Connectors and interfaces |
|||||||||
Ethernet interfaces |
10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 Unshielded Twisted Pair (UTP) cabling |
||||||||
100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling |
|||||||||
1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling |
|||||||||
1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling |
|||||||||
Indicator LEDs |
Per-port status: link integrity, disabled, activity |
||||||||
System status: System |
|||||||||
CAB-CONSOLE-RJ45 Console cable 6 ft. with RJ-45 |
|||||||||
CAB-CONSOLE-USB Console cable 6 ft. with USB Type A and mini-B connectors |
|||||||||
Power |
Use the supplied AC power cord to connect the AC power connector to an AC power outlet Models have external power supply |
||||||||
Management |
|||||||||
|
IF-MIB INET-ADDRESS-MIB OLD-CISCO-CHASSIS-MIB OLD-CISCO-FLASH-MIB OLD-CISCO-INTERFACES-MIB OLD-CISCO-IP-MIB OLD-CISCO-SYS-MIB OLD-CISCO-TCP-MIB OLD-CISCO-TS-MIB RFC1213-MIB RMON-MIB RMON2-MIB SNMP-FRAMEWORK-MIB SNMP-MPD-MIB SNMP-NOTIFICATION-MIB SNMP-TARGET-MIB SNMPv2-MIB TCP-MIB UDP-MIB |
||||||||
Standards |
|||||||||
|
IEEE 802.3ab 1000BASE-T IEEE 802.3z 1000BASE-X RMON I and II standards SNMP v1, v2c, and v3 IEEE 802.3az IEEE 802.3ae 10 Gigabit Ethernet IEEE 802.1ax |
||||||||
RFC compliance |
|||||||||
|
RFC 1256 — ICMP Router Discovery RFC 1305 — NTP RFC 1492 — TACACS RFC 1493 — Bridge MIB RFC 1542 — BOOTP extensions RFC 1901 — SNMP v2C RFC 1902-1907 — SNMP v2 RFC 1981 — Maximum Transmission Unit (MTU) Path Discovery IPv6 FRC 2068 — HTTP RFC 2131 — DHCP RFC 2138 — RADIUS RFC 2233 — IF MIB v3 |