C1000-16T-2G-L Catalyst 1000 16port GE, 2x1G SFP
105,008.20₽
Specifications |
Gigabit Ethernet / FE ports |
Uplink interfaces |
Fanless |
Dimensions (WxDxH in inches) |
Weight (kg) |
|
16 10/100/1000 RJ45 Data |
2 SFP |
Y |
10.56 x 10.69 x 1.73 |
1.78 |
Console ports |
|||||||||
RJ-45 Ethernet |
1 |
||||||||
USB mini-B |
1 |
||||||||
USB-A port for storage and Bluetooth console |
1 |
||||||||
Memory and processor |
|||||||||
CPU |
ARM v7 800 MHz |
||||||||
DRAM |
512 MB |
||||||||
Flash memory |
256 MB |
||||||||
Performance |
|||||||||
18 Gbps |
|||||||||
Switching bandwidth |
36 Gbps |
||||||||
Forwarding rate |
26.78 Mpps |
||||||||
MAC addresses |
16000 |
||||||||
IPv4 unicast direct routes |
542 |
||||||||
IPv4 unicast indirect routes |
256 |
||||||||
IPv6 unicast direct routes |
414 |
||||||||
IPv6 unicast indirect routes |
128 |
||||||||
IPv4 multicast routes and IGMP groups |
1024 |
||||||||
IPv6 multicast groups |
1024 |
||||||||
IPv4/MAC security ACEs |
600 |
||||||||
IPv6 security ACEs |
600 |
||||||||
Maximum active VLANs |
256 |
||||||||
VLAN IDs available |
4094 |
||||||||
Maximum STP instances |
64 |
||||||||
Maximum SPAN sessions |
4 |
||||||||
MTU-L3 packet |
9198 bytes |
||||||||
Jumbo Ethernet frame |
10,240 bytes |
||||||||
Dying Gasp |
Yes |
||||||||
MTBF in hours (data) |
2,165,105 |
||||||||
MTBF in hours (PoE) |
706,983 |
||||||||
MTBF in hours (Full PoE) |
— |
Environmental |
|||||||||
Operating temperature |
|||||||||
Sea level |
-5 to 50 deg C* |
||||||||
Up to 5,000ft (1500 m) |
-5 to 45 deg C |
||||||||
Upto 10,000 (3000 m) |
-5 to 40 deg C |
||||||||
Operating altitude |
10,000 ft (3,000m) |
||||||||
Operating relative humidity |
5% to 90% at 40 deg C (non-condensing) |
||||||||
Storage temperature |
-13 to 158F (-25 to 70C) |
||||||||
Storage altitude |
15,000 ft (4500m) |
||||||||
Storage relative humidit |
5% to 95% at 65 deg C (non-condensing) |
||||||||
*Note: |
● 50C operation is supported for short term operation only;
● When using C1000-8T-E-2G-L, C1000-8T-2G-L, C1000-8P-E-2G-L, C1000-8P-2G-L, C1000-8FP-E-2G-L, C1000-8FP-2G-L, C1000-16T-E-2G-L, C1000-16T-2G-L, C1000-16P-E-2G-L, C1000-16P-2G-L, C1000-16FP-2G-L, C1000-24T-4G-L, C1000-24P-4G-L with GLC-BX-U or GLC-BX-D SFP module, the thermal limitations are as follows:
◦ Up to 5,000 feet, the operation temperature should not exceed 45ºC. ◦ Up to 10,000 feet, the operation temperature should not exceed 40ºC. ● When using C1000-24T-4X-L, C1000-24P-4X-L with SFP-10G-ER or SFP-10G-ER-S SFP module, the thermal limitations are as follows:
◦ Up to 5,000 feet, the operation temperature should not exceed 45ºC. ◦ Up to 10,000 feet, the operation temperature should not exceed 40ºC. ● Minimum ambient temperature for cold start is at 0 deg C (32 deg F)
|
||||||||
Electrical |
Data |
Data Ext. PS |
|||||||
Voltage (auto ranging) |
110 to 220V AC in |
||||||||
Frequency |
50 to 60 Hz |
||||||||
Current |
0.16A to 0.26A |
0.19A to 0.31A |
|||||||
Power rating |
0.05 kVA |
0.05 kVA |
|||||||
Electrical |
PoE |
PoE Ext. PS |
|||||||
Voltage (auto ranging) |
110 to 220V AC in |
||||||||
Frequency |
50 to 60 Hz |
||||||||
Current |
0.24A to 0.28A |
0.14A to 0.24A |
|||||||
Power rating |
0.19 kVA |
0.20 kVA |
|||||||
Electrical |
Full PoE |
||||||||
Voltage (auto ranging) |
110 to 220V AC in |
||||||||
Frequency |
50 to 60 Hz |
||||||||
Current |
0.35A to 0.37A |
||||||||
Power rating |
0.45 kVA |
||||||||
Data |
Data Ext. PS |
||||||||
0% traffic |
14.52 |
14.4 |
|||||||
|
|
||||||||
10% traffic |
16.44 |
16.44 |
|||||||
|
|
||||||||
100% traffic |
16.68 |
16.68 |
|||||||
|
|
||||||||
Weighted average |
15.88 |
15.84 |
|||||||
|
|
||||||||
Power consumption (watts) |
PoE |
PoE Ext. PS |
|||||||
|
|
|
|||||||
0% traffic |
14.64 |
13.68 |
|||||||
|
|
||||||||
10% traffic |
16.56 |
15.48 |
|||||||
|
|
||||||||
100% traffic |
16.92 |
16.32 |
|||||||
|
|
||||||||
Weighted average |
16.04 |
15.16 |
|||||||
|
|
||||||||
Power consumption (watts) |
Full PoE |
||||||||
0% traffic |
14.4 |
||||||||
|
|||||||||
10% traffic |
16.68 |
||||||||
|
|||||||||
100% traffic |
16.8 |
||||||||
|
|||||||||
Weighted average |
15.96 |
||||||||
|
|||||||||
|
Note: The wattage rating on the power supply does not represent actual power draw. It indicates the maximum power draw possible by the power supply. This rating can be used for facility capacity planning. For PoE switches, cooling requirements are smaller than total power draw because a significant portion of the load is dissipated in the endpoints. |
Safety and compliance |
|||||||||
Safety |
UL 60950-1 Second Edition, CAN/CSA-C22.2 No. 60950-1 Second Edition, EN 60950-1 Second Edition, IEC 60950-1 Second Edition, AS/NZS 60950-1, IEC 62368-1, UL 62368-1 GB 4943.1-2011 |
||||||||
EMC: Emissions |
47CFR Part 15 Class A, AS/NZS CISPR32 Class A, CISPR32 Class A, EN55032 Class A, ICES-003 Class A, VCCI-CISPR32 Class A, EN61000-3-2, EN61000-3-3, KN32 Class A, CNS13438 Class A |
||||||||
EMC: Immunity |
EN55024 (including EN 61000-4-5), EN300386, KN35 |
||||||||
Environmental |
Reduction of Hazardous Substances (RoHS) including Directive 2011/65/EU |
||||||||
Telco |
Common Language Equipment Identifier (CLEI) code |
||||||||
U.S. government certifications |
USGv6 and IPv6 Ready Logo |
||||||||
Connectors and interfaces |
|||||||||
Ethernet interfaces |
10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 Unshielded Twisted Pair (UTP) cabling |
||||||||
100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling |
|||||||||
1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling |
|||||||||
1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling |
|||||||||
Indicator LEDs |
Per-port status: link integrity, disabled, activity |
||||||||
System status: System |
|||||||||
Console cables |
CAB-CONSOLE-RJ45 Console cable 6 ft. with RJ-45 |
||||||||
CAB-CONSOLE-USB Console cable 6 ft. with USB Type A and mini-B connectors |
|||||||||
Power |
Use the supplied AC power cord to connect the AC power connector to an AC power outlet Models have external power supply |
||||||||
Management |
|||||||||
CISCO-PORT-QOS-MIB CISCO-PORT-SECURITY-MIB CISCO-PORT-STORM-CONTROL-MIB CISCO-PRODUCTS-MIB CISCO-PROCESS-MIB CISCO-RTTMON-MIB CISCO-SMI-MIB CISCO-STP-EXTENSIONS-MIB CISCO-SYSLOG-MIB CISCO-TC-MIB CICSO-TCP-MIB CISCO-UDLDP-MIB CISCO-VLAN-IFTABLE CISCO-VLAN-MEMBERSHIP-MIB CISCO-VTP-MIB ENTITY-MIB ETHERLIKE-MIB IEEE8021-PAE-MIB IEEE8023-LAG-MIB |
|||||||||
Standards |
|||||||||
|
IEEE 802.3ad IEEE 802.3af and IEEE 802.3at IEEE 802.3ah (100BASE-X single/multimode fiber only) IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports IEEE 802.3 10BASE-T IEEE 802.3u 100BASE-TX |
||||||||
RFC compliance |
|||||||||
|
RFC 1256 — ICMP Router Discovery RFC 1305 — NTP RFC 1492 — TACACS RFC 1493 — Bridge MIB RFC 1542 — BOOTP extensions RFC 1901 — SNMP v2C RFC 1902-1907 — SNMP v2 RFC 1981 — Maximum Transmission Unit (MTU) Path Discovery IPv6 FRC 2068 — HTTP RFC 2131 — DHCP RFC 2138 — RADIUS RFC 2233 — IF MIB v3 |