C1000-8T-E-2G-L Catalyst 1000 8port GE, Ext PS, 2x1G SFP

680.66

Power Cables

Console Cables

Power Clip

Cable Guard

SmartNet

Сумма:

Add-ons total:

Всего:

Вес: 0 kg
скачать как CSV

Specifications

Gigabit Ethernet / FE ports

Uplink interfaces

Fanless

Dimensions (WxDxH in inches)

Weight (kg)

8 10/100/1000 RJ45 Data

2 SFP/ RJ-45 combo

Y

10.56 x 7.28 x 1.73

1.55

Console ports

RJ-45 Ethernet

1

USB mini-B

1

USB-A port for storage and Bluetooth console

1

Memory and processor

CPU

ARM v7 800 MHz

DRAM

512 MB

Flash memory

256 MB

Performance

Forwarding bandwidth

10 Gbps

Switching bandwidth

20 Gbps

Forwarding rate
(64‑byte L3 packets)

14.88 Mpps

MAC addresses

16000

IPv4 unicast direct routes

542

IPv4 unicast indirect routes

256

IPv6 unicast direct routes

414

IPv6 unicast indirect routes

128

IPv4 multicast routes and IGMP groups

1024

IPv6 multicast groups

1024

IPv4/MAC security ACEs

600

IPv6 security ACEs

600

Maximum active VLANs

256

VLAN IDs available

4094

Maximum STP instances

64

Maximum SPAN sessions

4

MTU-L3 packet

9198 bytes

Jumbo Ethernet frame

10,240 bytes

Dying Gasp

Yes

MTBF in hours (data)

2,171,669

MTBF in hours (PoE)

1,786,412, 1,706,649 (External PS)

MTBF in hours (Full PoE)

1,706,649

Environmental

Operating temperature

Sea level

-5 to 50 deg C*

Up to 5,000ft (1500 m)

-5 to 45 deg C

Upto 10,000 (3000 m)

-5 to 40 deg C

Operating altitude

10,000 ft (3,000m)

Operating relative humidity

5% to 90% at 40 deg C (non-condensing)

Storage temperature

-13 to 158F (-25 to 70C)

Storage altitude

15,000 ft (4500m)

Storage relative humidit

5% to 95% at 65 deg C (non-condensing)

*Note:

●  50C operation is supported for short term operation only;
●  When using C1000-8T-E-2G-L, C1000-8T-2G-L, C1000-8P-E-2G-L, C1000-8P-2G-L, C1000-8FP-E-2G-L, C1000-8FP-2G-L, C1000-16T-E-2G-L, C1000-16T-2G-L, C1000-16P-E-2G-L, C1000-16P-2G-L, C1000-16FP-2G-L, C1000-24T-4G-L, C1000-24P-4G-L with GLC-BX-U or GLC-BX-D SFP module, the thermal limitations are as follows:

◦    Up to 5,000 feet, the operation temperature should not exceed 45ºC.

◦    Up to 10,000 feet, the operation temperature should not exceed 40ºC.

●  When using C1000-24T-4X-L, C1000-24P-4X-L with SFP-10G-ER or SFP-10G-ER-S SFP module, the thermal limitations are as follows:

◦    Up to 5,000 feet, the operation temperature should not exceed 45ºC.

◦    Up to 10,000 feet, the operation temperature should not exceed 40ºC.

●  Minimum ambient temperature for cold start is at 0 deg C (32 deg F)

Electrical

Data

Data Ext.PS

Voltage (auto ranging)

110 to 220V AC in

Frequency

50 to 60 Hz

Current

0.13A to 0.22A

0.16A to 0.26A

Power rating
(maximum consumption)

0.04 kVA

0.017 kVA

Electrical

PoE

PoE Ext. PS

Voltage (auto ranging)

110 to 220V AC in

Frequency

50 to 60 Hz

Current

0.22A to 0.27A

0.22A to 0.37A

Power rating
(maximum consumption)

0.11 kVA

0.087 kVA

Electrical

Full PoE

Full PoE Ext. PS

Voltage (auto ranging)

110 to 220V AC in

Frequency

50 to 60 Hz

Current

0.23A to 0.28A

0.15A to 0.2A

Power rating
(maximum consumption)

0.15 kVA

0.15 kVA

Power consumption (watts)

Data

Data Ext.PS

0% traffic

14.04

13.15

10% traffic

14.06

13.76

100% traffic

14.26

14

Weighted average

14.12

13.64

Power consumption (watts)

PoE

PoE Ext. PS

 

0% traffic

10.22

9.13

10% traffic

12.02

15.39

100% traffic

12.19

15.71

Weighted average

11.48

13.41

Power consumption (watts)

Full PoE

Full PoE Ext. PS

0% traffic

13.44

14.3

10% traffic

14.4

14.9

100% traffic

14.52

15.7

Weighted average

14.12

14.97

Note: The wattage rating on the power supply does not represent actual power draw. It indicates the maximum power draw possible by the power supply. This rating can be used for facility capacity planning. For PoE switches, cooling requirements are smaller than total power draw because a significant portion of the load is dissipated in the endpoints.

Safety and compliance

Safety

UL 60950-1 Second Edition, CAN/CSA-C22.2 No. 60950-1 Second Edition, EN 60950-1 Second Edition, IEC 60950-1 Second Edition, AS/NZS 60950-1, IEC 62368-1, UL 62368-1

GB 4943.1-2011

EMC: Emissions

47CFR Part 15 Class A, AS/NZS CISPR32 Class A, CISPR32 Class A, EN55032 Class A, ICES-003 Class A, VCCI-CISPR32 Class A, EN61000-3-2, EN61000-3-3, KN32 Class A, CNS13438 Class A

EMC: Immunity

EN55024 (including EN 61000-4-5), EN300386, KN35

Environmental

Reduction of Hazardous Substances (RoHS) including Directive 2011/65/EU

Telco

Common Language Equipment Identifier (CLEI) code

U.S. government certifications

USGv6 and IPv6 Ready Logo

Connectors and interfaces

Ethernet interfaces

10BASE-T ports: RJ-45 connectors, 2-pair Category 3, 4, or 5 Unshielded Twisted Pair (UTP) cabling

100BASE-TX ports: RJ-45 connectors, 2-pair Category 5 UTP cabling

1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling

1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Category 5 UTP cabling

Indicator LEDs

Per-port status: link integrity, disabled, activity

System status: System

Console cables

CAB-CONSOLE-RJ45 Console cable 6 ft. with RJ-45

CAB-CONSOLE-USB Console cable 6 ft. with USB Type A and mini-B connectors

Power

Use the supplied AC power cord to connect the AC power connector to an AC power outlet

Models have external power supply

Management

BRIDGE-MIB

CISCO-CABLE-DIAG-MIB

CISCO-CDP-MIB

CISCO-CLUSTER-MIB

CISCO-CONFIG-COPY-MIB

CISCO-CONFIG-MAN-MIB

CISCO-DHCP-SNOOPING-MIB

CISCO-ENTITY-VENDORTYPE-OID-MIB

CISCO-ENVMON-MIB

CISCO-ERR-DISABLE-MIB

CISCO-FLASH-MIB

CISCO-FTP-CLIENT-MIB

CISCO-IGMP-FILTER-MIB

CISCO-IMAGE-MIB

CISCO-IP-STAT-MIB

CISCO-LAG-MIB

CISCO-MAC-NOTIFICATION-MIB

CISCO-MEMORY-POOL-MIB

CISCO-PAGP-MIB

CISCO-POE-EXTENSIONS-MIB

Standards

IEEE 802.1D STP

IEEE 802.1p CoS Prioritization

IEEE 802.1Q VLAN

IEEE 802.1s

IEEE 802.1w

IEEE 802.1X

IEEE 802.1ab LLDP

Bluetooth v4.0

RFC 768 — UDP

RFC 783 — TFTP

RFC 791 — IP

RFC 792 — ICMP

RFC 793 — TCP

RFC 826 — ARP

RFC 854 — Telnet

RFC 951 — Bootstrap Protocol (BOOTP)

RFC 959 — FTP

RFC 1112 — IP Multicast and IGMP

RFC 1157 — SNMP v1

RFC 1166 — IP Addresses