N9K-C93108TC-EX-RF 48 x 100M/1/10GBASE-T ports and 6 x 40/100-Gbps QSFP28 ports REMANUFACTURED

12,422.78$

Fan

Software License Tiers

Additional Support

Perpetual Licenses

Switch Mode

Airflow Mode

Accessory Kit

Power Supply

Power Cable

1/10G Transceiver and Cable Options

40G Transceiver and Cable Options

100G Transceiver and Cable Options

SmartNet

Subtotal:

Add-ons total:

Total:

Weight: 0 kg
скачать как CSV

Features

Ports

48 x 100-Mbps/1/10GBASE-T and 6 x 40/100-Gbps QSFP28 ports

CPU

4 cores

System memory

24 GB

SSD drive

64 GB

System buffer

40 MB

Management ports

2 ports: 1 RJ-45 and 1 SFP

USB ports

1

RS-232 serial ports

1

Power supplies (up to 2)

500W AC, 650W AC, 930W DC, or 1200W HVAC/HVDC

Typical power* (AC/DC)

290W

Maximum power* (AC/DC)

499W

BTU/hr

1703

Input voltage (AC)

100 to 240V

Input voltage
(high-voltage AC [HVAC])

200 to 277V

Input voltage (DC)

–48 to –60V

Input voltage
(high-voltage DC [HVDC])

–240 to –380V

Frequency (AC)

50 to 60 Hz

Fans

4

Airflow

Port-side intake and exhaust

Physical dimensions
(H x W x D)

1.72 x 17.3 x 22.5 in.
(4.4 x 43.9 x 57.1 cm)

Acoustics

48.6 dBA at 40% fan speed, 65.2 dBA at 70% fan speed, and 76.5 dBA at 100% fan speed

RoHS compliance

Yes

MTBF

366,130 hours

Minimum ACI image

ACI-N9KDK9-12.0

Minimum NX-OS image

NXOS-703I4.3

* Typical and maximum power values are based on input drawn from the power circuit. The power supply value (for example, 1100W AC power supply: NXA-PAC-1100W-PI) is based on the output rating to the inside of the switch.

 

Hardware performance and scalability specifications*

Maximum number of Longest Prefix Match (LPM) routes**

896,000

Maximum number of IP host entries**

896,000

Maximum number of MAC address entries**

256,000

Maximum number of multicast routes

32,000

Number of Interior Gateway Management Protocol (IGMP) snooping groups

Shipping: 8,000

Maximum: 32,000

Maximum number of Cisco Nexus 2000 Series Fabric Extenders per switch

16

Maximum number of Access Control List (ACL) entries

Per slice of the forwarding engine:

4000 ingress

2000 egress

Total (2 forwarding slices):

8000 ingress

4000 egress

Maximum number of VLANs

4096**

Number of Virtual Routing and Forwarding (VRF) instances

Shipping: 1,000

Maximum: 16,000

Maximum number of ECMP paths

64

Maximum number of port channels

512

Maximum number of links in a port channel

32

Number of active SPAN sessions

4

Maximum number of VLAN’s in Rapid per-VLAN Spanning Tree (RPVST) instances

3,967

Maximum number of Hot-Standby Router Protocol (HSRP) groups

490

Number of Network Address Translation (NAT) entries

1,023

Maximum number of Multiple Spanning Tree (MST) instances

64

Flow-table size used for Cisco Tetration Analytics platform***

64,000

Number of Queues

8

* More templates and greater scalability are on the roadmap. Refer to the Cisco Nexus 9000 Series Verified Scalability Guide documentation for the latest exact scalability values validated for specific software.
** Raw capacity of flow table.
***127 VLANs out of 4096 are reserved.

 

Environmental properties

Operating temperature

32 to 104°F (0 to 40°C)

Nonoperating (storage) temperature

–40 to 158°F (–40 to 70°C)

Humidity

5 to 95% (noncondensing)

Altitude

0 to 13,123 ft (0 to 4000m)

 

Weight

Cisco Nexus 93108TC-EX without power supplies or fans 17.7 lb (8.0 kg)

500W AC power supply

2.42 lb (1.1 kg)

650W AC power supply

2.42 lb (1.1 kg)

930W DC power supply

2.42 lb (1.1 kg)

1200W HVDC/HVAC power supply

2.42 lb (1.1 kg)

Fan tray: NXA-FAN-30CFM-F or NXA-FAN-30CFM-B

0.26 lb (0.12 kg)

 

Regulatory standards compliance: safety and EMC

Regulatory compliance

Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC

Safety

NEBS

● UL 60950-1 Second Edition
● CAN/CSA-C22.2 No. 60950-1 Second Edition
● EN 60950-1 Second Edition
● IEC 60950-1 Second Edition
● AS/NZS 60950-1
● GB4943

EMC: Emissions

● 47CFR Part 15 (CFR 47) Class A
● AS/NZS CISPR22 Class A
● CISPR22 Class A
● EN55022 Class A
● ICES003 Class A
● VCCI Class A
● EN61000-3-2
● EN61000-3-3
● KN22 Class A
● CNS13438 Class A

EMC: Immunity

● EN55024
● CISPR24
● EN300386
● KN 61000-4 series

RoHS

The product is RoHS-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors