Cisco Catalyst IE-3400-8T2S-A Rugged Series
€9,729.31
Features |
Robust industrial design |
● Built for harsh environments and temperature ranges (-40°C to 75°C)
● Fanless, convection-cooled with no moving parts for extended durability
● Hardened for vibration, shock and surge, and electrical noise immunity
● Complies with multi-industry specifications for automation, ITS, and substation environments
● Improves uptime, performance, and safety of industrial systems and equipment
● Covers a wide range of Power over Ethernet (PoE) (up to IEEE ® 802.3bt type 4) application requirements
● Alarm I/O for monitoring and signaling to external equipment
|
Full Gigabit Ethernet interfaces with 10G uplink variants |
● Provides secure access for new high-speed applications in the industrial space
● There are two base system port configurations available: 2 ports of 1GE uplinks or 2 ports of 10G uplinks:
◦ Packs up to 10 ports — 2x 10G Small Form-Factor Pluggable (SFP ) uplinks plus 8x 1GE copper RJ45 downlink ports (with IEEE® 802.3bt PoE or non-PoE) in a small form-factor base system ◦ Packs up to 10 ports of GE — 2x 1GE Small Form-Factor Pluggable (SFP) uplinks plus 8x 1GE copper RJ45 downlink ports (with PoE or non PoE) in a small form-factor base system ● Expandable
◦ to up to 26 ports of GE by attaching one of 8 compatible modules (copper, PoE, fiber and 2.5G with IEEE® 802.3bt type 4 options) ◦ to up to 24 ports of GE plus 2 ports of 10G by attaching one of the 8 compatible modules (copper, PoE, fiber and 2.5G with IEEE® 802.3bt type 4 options) ● Connects high-speed wireless access points (802.11n, 802.11ac, 802.11ac WAVE 2, 802.11ax)
● Enables Ultra High-Definition (UHD), PTZ IP cameras, Programmable Logic Controllers (PLC) and Wi-Fi 6 Access Points
● Delivers multiple rings and redundant ring topologies for new network configurations
● Extends geographical scalability where longer-distance connectivity is required
|
High-density industrial Power over Ethernet (PoE) |
● Supports
◦ up to 24x PoE/PoE ports or 4x 802.3bt type 4 ports (with 2.5G expansion module) with the all GE PoE enabled base [Power budget — 360W] ◦ up to 24x PoE/PoE ports or 8x «802.3bt type 3» ports or 4x «802.3bt type 4» ports with the 10G, PoE enabled system [Power budget – 480Watts] ● Controls costs by limiting wiring, distribution panels, and circuit breakers
● Reduces equipment needs, thus requiring less space and reducing heat dissipation
● Enables ready-to-use PoE devices, such as IP phones, cameras, and wireless access points
|
User-friendly GUI, called WebUI |
● Allows for easy configuration and monitoring
● Eliminates the need for more complex, terminal emulation programs
● Reduces the cost of deployment
|
SwapDrive for zero-configuration replacement |
● True zero-configuration and simple switch replacement in the event of a failure
● No networking expertise required
● Helps ensure fast recovery
|
Full Flexible NetFlow (FNF) |
● Provides enhanced flow and threat visibility
● Enables optimization of the network infrastructure, reduces operation costs, and improves capacity planning and security incident detection
|
IE3400 Hardware configurations |
Product number |
Total ports |
10/100/1000 RJ45 Copper ports |
100/1000 SFP ports |
1GE/2.5G RJ45 Copper ports |
Software license (Default) |
PoE/ PoE ( ) budget |
IE-3400-8T2S-A |
10 |
8 |
2 |
N.A. |
Network Advantage |
N.A. |
IE3400 Hardware Specifications |
PoE power budget |
Not applicable |
Removable storage |
USB2,3, SD card2 |
Alarms |
2 alarms in, 1 alarm out |
Console ports |
1 RS-232 (via RJ-45), 1 USB Mini Type B |
Power inputs |
Dual DC power input |
IE3400 physical configurations |
Dimensions (H x W x D) |
Weight |
Mounting |
6 in. X 3.6 in. X 5.3 in. |
3.8 lbs |
DIN rail |
Front View
Top view
IE3400 performance and scalability features |
Forwarding rate |
Line rate for all ports and all packet sizes |
Number of queues |
8 |
Unicast MAC addresses |
8K |
Internet Group Management Protocol (IGMP multicast groups) |
1K |
No. of VLANs |
256 |
IPv4 Indirect routes1 |
2000 |
IPv6 Indirect routes1 |
512 |
Spanning Tree Protocol (STP) instances |
128 |
Access Control Entries (PACL/VACL/RACL) |
3K |
DRAM |
4 GB |
Flash [User Accessible] |
1.5 GB |
SD card capacity2 |
4 GB |
Jumbo Frames |
2000 bytes |
IE3300 power specifications |
Input voltage range |
Redundant DC input voltage: 9.6 to 60VDC |
Input current |
6.3A |
Power consumption1 |
36W |
1Power consumption for non PoE supported model is measured at 12V and for the PoE supported model is measured at 54V. Power consumption does not include PoE power.
Power supply options |
Product ID |
Wattage |
Rated nominal input operating range |
PoE/PoE support1 |
PWR-IE50W-AC= |
50W |
AC 100-240V/1.25A 50-60Hz |
No |
PWR-IE50W-AC-IEC= |
50W |
AC 90-264V |
No |
PWR-IE50W-AC-L=2 |
50W |
AC 100-240V/1.0A 50-60Hz |
No |
PWR-IE65W-PC-AC= |
65W |
AC 100-240V/1.4A 50-60Hz |
Yes |
PWR-IE65W-PC-DC= |
65W |
DC 24-48VDC/4.5A |
Yes |
PWR-IE170W-PC-AC= |
170W |
AC 100-240V/2.3A 50-60Hz |
Yes |
PWR-IE170W-PC-DC= |
170W |
DC 12-54VDC/23A |
Yes |
PWR-IE240W-PCAC-L=2 |
240W |
AC 100-240V/2.5A 50-60Hz |
Yes |
PWR-IE480W-PCAC-L=2 |
480W |
AC 100-240V/5.0A 50-60Hz |
Yes |
Key supported software features (Network Essentials License) |
Network Essentials License (Perpetual) |
Features |
Layer 2 switching |
IEEE 802.1, 802.3 standard, NTP, UDLD, CDP, LLDP, unicast MAC filter, PaGP, LACP VTPv2, VTPv3, EtherChannel, Q-in-Q tunneling, voice VLAN, PVST , MSTP, and RSTP |
Multicast |
IGMPv1, v2, v3 snooping, IGMP filtering, IGMP querier |
Management |
WebUI, MIB, SmartPort, SNMP, syslog, DHCP server, SPAN session, RSPAN, FSPAN, Express setup, NETCONF, RESTCONF |
Security |
Port security, 802.1x, Dynamic Host Configuration Protocol (DHCP) snooping, dynamic ARP inspection, IP source guard, guest VLAN, MAC authentication bypass, 802.1x multidomain authentication, storm control — unicast, multicast, broadcast, SCP, SSH, SNMPv3, TACACS , RADIUS server/client, MAC address notification, BPDU guard, Access Lists(PACL/RACL/VACL), SUDI 2099 (Secure Unique Device identifier), Full Flexible NetFlow (FNF), MACsec-128 |
Quality of Service (QoS) |
Ingress policing, rate limit, egress queuing/shaping, auto QoS |
IPv6 |
IPv6 host support, SNMP over IPv6, HTTP/HTTP(s) over IPv6, SNMP over IPv6, Syslog over IPv6, DHCPv6 relay source, DHCPv6 bulk lease query (RFC 5460), IPv6 stateless Auto Config, SCP/SSH, Radius, TACACS , NTP over IPv6, IPv6 VRF aware BGPv6, IPV6 ND cache expire, IPv6 support for TFTP, IPv6 DNS transport, IPv6 QoS, IPv6 FHS RA Guard, IPv6 FHS DHCPv6 Guard |
Layer 3 routing |
Inter-VLAN routing, Static routing |
Industrial Ethernet |
CIP Ethernet/IP, 3IEEE 1588 PTP v2 (default and power), PROFINET |
Redundancy |
Resilient Ethernet Protocol (REP) ring, PROFINET-Multi Ring Protocol (MRP), REP Negotiated, Fast REP, Parallel redundancy protocol (PRP)2, PTP over PRP |
Utility |
Dying gasp, SCADA protocol classification – GOOSE messaging, MODBUS TCP/IP |
Automation |
YANG, NETCONF, RESTCONF |
Industrial Management |
Layer 2 switching with 1:1 switch Network Address Translation (L2NAT)1 |
IOx |
Container (Native docker) |
Key supported software features (Network Advantage License) |
Network Advantage License (Perpetual) |
Features |
IP routing Protocols |
OSPF (v4 and v6), BGP (v4 and v6), ISIS (v4 and v6), RIP (v1 and v2), EIGRP (v4 and v6), Policy based routing (PBR), VRRP (v4 and v6), HSRP (v4 and v6) |
Virtualization |
Vrf-lite |
Security |
MACsec-256, SGT/SGACL1 |
IP Multicast |
PIM sparse mode (PIM-SM), PIM dense mode (PIM-DM), and PIM sparse-dense mode, MSDP, Multicast routing BSR (IPv4/IPv6), Auto RP (IPv4), Embedded RP (IPv6) |
Cisco IE3300 Cisco DNA Essentials and Cisco DNA Advantage license |
Feature |
Description |
Cisco DNA Essentials |
Cisco DNA Advantage |
Cisco DNA Center |
Discovery, Topology, Inventory, software image management |
Yes |
Yes |
Visibility |
Cisco DNA assurance, Device 360 |
Yes |
Yes |
Day-zero network bring-up automation |
Cisco Network Plug-and-Play application |
Yes |
Yes |
Software-defined Access |
Policy based automation, IE3400 can function as an SD-Access Policy extended node |
N.A. |
Yes |
Compliance Specifications |
Industrial Automation Control System |
IEC 62443-4-1 IEC 62443-4-2 |
Electromagnetic emissions |
FCC 47 CFR Part 15 subpart B Class A EN 55032/CISPR 32 Class A VCCI Class A AS/NZS CISPR 32 Class A CISPR 11 Class A ICES 003 Class A CNS 13438 Class A KN 32 Class A EN 300 386 |
Electromagnetic immunity |
CISPR 24 EN 55024 KN 35 EN 61000-4-2 Electro Static Discharge (air – 15kV, contact – 8kV) EN 61000-4-3 Radiated RF (10V/m UTP, 20V/m STP) EN 61000-4-4 Electromagnetic Fast Transients (4kV) EN 61000-4-5 Surge (2KV/1KV Power, 4KV STP) EN 61000-4-6 Conducted RF (10Vrms UTP) EN 61000-4-8 Power Frequency Magnetic Field (1000A/m) EN 61000-4-10 Damped Oscillatory Magnetic Field (100 A/m) EN 61000-4-16 Conducted CM Disturbances (30V, Cont/ 300V, 1 sec) EN 61000-4-17 Ripple Immunity DC Power (10%) EN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz) EN-61000-4-29 DC Voltage Dips and Interruptions |
Industry standards |
EN 61000-6-2 Industrial Immunity EN 61000-6-4 Industrial Emissions EN 61000-6-1 Light Industrial Immunity EN 61326-1 Measurement, Control and Laboratory Equipment IEEE 1613 Electric Power Stations Communications Networking EN/IEC 61850 -3 Electric Substations Communications Networking EN50121-4 Railway – Signaling and Telecommunications Apparatus ODVA Industrial EtherNet/IP NEMA TS 2-2016 IP30 |
Safety standards and certifications |
Information Technology Equipment: UL/CSA 60950-1, CB to IEC 60950-1 with all country deviations UL/CSA 62368-1, CB to IEC 62368-1 with all country deviations Industrial floor (control equipment): UL/CSA 61010-2-201 CB report and certificate to IEC/EN 61010-2-201 Hazardous Locations: UL121201(Class l, Div 2, groups A-D) CSA 213 (Class l, Div 2, groups A-D) UL/CSA 60079-0, -15 (Class l, Zone 2, Gc/IIC) IEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc/IIC) EN 60079-0, -15 ATEX certifícate (Class l, Zone 2, Gc/IIC) cabinet enclosure required |
Operating environment |
Operating temperature: -40°C to 70°C (40 LFM vented enclosure) -40°C to 60°C (sealed enclosure) -34°C to 75°C (Min. 200 LFM fan or blower-equipped enclosure) 85°C (type tested for 16 hours) Altitude: up to 15,000 feet |
Storage environment |
Temperature: -40°C to 85°C Altitude: 15,000 feet IEC 60068-2-14 |
Humidity |
Relative humidity of 5% to 95% non-condensing IEC 60068-2-78 IEC 60068-2-30 |
Shock and vibration |
IEC 60068-2-27 (operational shock, 50G, 3ms, half sine) IEC 60068-2-27 (non-operational shock, 65-80G, 9ms, trapezoidal) IEC 60068-2-6 (vibration-sinusiodal, 5Hz-150Hz) |
Corrosion |
IEC 60068-2-52 (salt fog) IEC 60068-2-60 (flowing mixed gas) |
Warranty |
Five-year limited hardware warranty on all IE3400 product IDs and all Industrial Ethernet (IE) power supplies. See more information under the Warranty section |
MTBF information |
549,808 |
Management and standards |
IEEE standards |
IEEE 802.1D MAC Bridges, STP IEEE 802.1p Layer2 COS prioritization IEEE 802.1q VLAN IEEE 802.1s Multiple Spanning-Trees IEEE 802.1w Rapid Spanning-Tree IEEE 802.1x Port Access Authentication IEEE 802.1AB LLDP IEEE 802.3ad Link Aggregation (LACP) IEEE 1588v2 PTP Precision Time Protocol |
IEEE 802.3ah 100BASE-X SMF/MMF only IEEE 802.3x full duplex on 10BASE-T IEEE 802.3 10BASE-T specification IEEE 802.3u 100BASE-TX specification IEEE 802.3ab 1000BASE-T specification IEEE 802.3z 1000BASE-X specification IEEE 802.3af Power over Ethernet IEEE 802.3 at Power over Ethernet plus |
RFC compliance |
RFC 768: UDP RFC 783: TFTP RFC 791: IPv4 protocol RFC 792: ICMP RFC 793: TCP RFC 826: ARP RFC 854: Telnet RFC 959: FTP RFC 1157: SNMPv1 RFC 1901,1902-1907 SNMPv2 RFC 2273-2275: SNMPv3 RFC 2571: SNMP Management RFC 1166: IP Addresses RFC 1256: ICMP Router Discovery RFC 1305: NTP RFC 951: BootP |
RFC 1492: TACACS RFC 1493: Bridge MIB Objects RFC 1534: DHCP and BOOTP interoperation RFC 1542: Bootstrap Protocol RFC 1643: Ethernet Interface MIB RFC 1757: RMON RFC 2068: HTTP RFC 2131, 2132: DHCP RFC 2236: IGMP v2 RFC 3376: IGMP v3 RFC 2474: DiffServ Precedence RFC 3046: DHCP Relay Agent Information Option RFC 3580: 802.1x RADIUS RFC 4250-4252: SSH Protocol RFC 5460: DHCPv6 bulk lease query |
SNMP MIB objects |
802.1X MIB CISCO-DHCP-SNOOPING-MIB CISCO-UDLDP-MIB CISCO-ENVMON-MIB CISCO-PRIVATE-VLAN-MIB CISCO-PAE-MIB Cisco-Port-QoS-MIB CISCO-ERR-DISABLE-MIB CISCO- PROCESS-MIB LLDP-MIB CiscoMACNotification-MIB CISCO-CONFIG-COPY-MIB LLDP-MED-MIB Bridge-MIB CISCO-CAR-MIB CISCO-LAG-MIB CISCO-SYSLOG-MIB CISCO-FTP-CLIENT-MIB CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB CISCO-VLAN-MEMBERSHIP-MIB Cisco-REP-MIB CISCO-PORT-STORM-CONTROL-MIB CISCO-CDP-MIB CISCO-IP-STAT-MIB CISCO-LICENSE-MGMT-MIB CISCO-STP-EXTN-MIB CISCO-VTP-MIB IEEE8023-LAG-MIB SMON-MIB CISCO-ACCESS-ENVMON-MIB CISCO-CALLHOME-MIB CISCO-CONFIG-MAN-MIB CISCO-FLASH-MIB CISCO-ENTITY-SENSOR-MIB IP-MIB CISCO-PAGP-MIB |
CISCO-IF-EXTENSION-MIB CISCO-IMAGE-MIB CISCO-MEMORY-POOL-MIB CISCO-PING-MIB SNMP-TARGET-EXT-MIB IF_MIB ENTITY-MIB LLDP-EXT-PNO-MIB NOTIFICATION-LOG-MIB OLD-CISCO-CPU-MIB ETHERLIKE-MIB OLD-CISCO-SYSTEM-MIB OLD-CISCO-MEMORY-MIB RMON-MIB SNMP-COMMUNITY-MIB SNMP-FRAMEWORK-MIB SNMP-PROXY-MIB SNMP-MPD-MIB SNMP-NOTIFICATION-MIB SNMP-TARGET-MIB SNMP-USM-MIB CISCO-DATACOLLECTION-MIB CISCO-CABLE-DIAG-MIB CISCO-PORT-SECURITY-MIB BULK_FILE_MIB NAC-NAD-MIB CISCO-ENTITY-ALARAM-MIB SNMP-VIEW-BASED-ACM-MIB CISCO-MAC-AUTH-BYPASS-MIB CISCO-AUTH-FRAMEWORK-MIB CISCO-BRIDGE-Ext-MIB SNMPv2-MIB CISCO-ENTITY-VENDORTYPE-OID-MIB CISCO-PRODUCTS-MIB IP-FORWARD-MIB BGP-CISCO-BGP-MIBv2 |
SFP Support |
Product ID |
Specifications |
SFP type |
Temperature range1 |
Maximum distance |
Cable type |
Dom support |
GLC-FE-100FX-RGD |
100BASE-FX |
FE |
IND |
2 km |
Multimode fiber (MMF) |
No |
GLC-FE-100LX-RGD |
100BASE-LX10 |
FE |
IND |
10 km |
Single-Mode Fiber (SMF) |
No |
GLC-FE-100FX |
100BASE-FX |
FE |
COM |
2 km |
MMF |
No |
GLC-FE-100LX |
100BASE-LX10 |
FE |
COM |
10 km |
SMF |
No |
GLC-FE-100EX |
100BASE-EX |
FE |
COM |
40 km |
SMF |
No |
GLC-FE-100ZX |
100BASE-ZX |
FE |
COM |
80 km |
SMF |
No |
GLC-FE-100BX-U |
100BASE-BX10 |
FE |
COM |
10 km |
SMF |
No |
GLC-FE-100BX-D |
100BASE-BX10 |
FE |
COM |
10 km |
SMF |
No |
GLC-SX-MM-RGD |
1000BASE-SX |
GE |
IND |
220-550 m |
MMF |
Yes |
GLC-LX-SM-RGD |
1000BASE-LX/LH |
GE |
IND |
550 m/10 km |
MMF/SMF |
Yes |
GLC-ZX-SM-RGD |
1000BASE-ZX |
GE |
IND |
70 km |
SMF |
Yes |
SFP-GE-S |
1000BASE-SX |
GE |
EXT |
220-550 m |
MMF |
Yes |
SFP-GE-L |
1000BASE-LX/LH |
GE |
EXT |
550 m/10 km |
MMF/SMF |
Yes |
SFP-GE-Z |
1000BASE-ZX |
GE |
EXT |
70 km |
SMF |
Yes |
GLC-BX-U |
1000BASE-BX10 |
GE |
COM |
10 km |
SMF |
Yes |
GLC-BX-D |
1000BASE-BX10 |
GE |
COM |
10 km |
SMF |
Yes |
GLC-SX-MM |
1000BASE-SX |
GE |
COM |
220-550 m |
MMF |
Yes |
GLC-LH-SM |
1000BASE-LX/LH |
GE |
COM |
550 m/10 km |
MMF/SMF |
Yes |
GLC-ZX-SM |
1000BASE-ZX |
GE |
COM |
70 km |
SMF |
Yes |
GLC-EX-SMD |
1000BASE-EX |
GE |
COM |
40 km |
SMF |
Yes |
GLC-TE |
1000BASE-T |
GE |
EXT |
100 m |
Cat5e |
No |
GLC-BX40-U-I= |
1000BASE-BX40 |
GE |
IND |
40 km |
SMF |
Yes |
GLC-BX40-D-I= |
1000BASE-BX40 |
GE |
IND |
40 km |
SMF |
Yes |
GLC-BX40-DA-I= |
1000BASE-BX40 |
GE |
IND |
40 km |
SMF |
Yes |
GLC-BX80-U-I= |
1000BASE-BX80 |
GE |
IND |
80 km |
SMF |
Yes |
GLC-BX80-D-I= |
1000BASE-BX80 |
GE |
IND |
80 km |
SMF |
Yes |
GLC-SX-MMD= |
1000BASE-SX |
GE |
EXT |
550 m |
MMF |
Yes |
GLC-LH-SMD= |
1000BASE-LX/LH |
GE |
EXT |
550m/10km |
MMF/SMF |
Yes |
GLC-ZX-SMD= |
1000BASE-ZX |
GE |
EXT |
70 km |
SMF |
Yes |
GLC-T-RGD= |
1000BASE-T |
GE |
IND |
100 m |
Copper |