Cisco Catalyst C9800-40-K9 Wireless Controller
20,142.54$
Features |
Maximum number of access points |
Up to 2000 |
Maximum number of clients |
32,000 |
Maximum throughput |
Up to 40 Gbps |
Maximum WLANs |
4096 |
Maximum VLANs |
4096 |
Maximum site tags |
2000 |
Maximum Flex® APs per site |
100 |
Maximum policy tags |
2000 |
Maximum RF tags |
2000 |
Maximum RF profiles |
4000 |
Maximum policy profiles |
1000 |
Maximum Flex profiles |
2000 |
Interfaces |
4x 10G/1x 1G SFP /SFP |
Power supply |
AC power with optional redundant AC power |
Maximum power consumption |
381W |
Deployment modes |
Centralized, Cisco FlexConnect®, and Fabric Wireless (SD-Access) |
Form factor |
1RU |
License |
Smart License enabled |
Operating system |
Cisco IOS XE |
Management |
Cisco DNA Center, Cisco Prime® Infrastructure, integrated WebUI, and third party (open standards APIs)* |
Interoperability |
AireOS-based controllers |
Policy engine |
Cisco Identity Services Engine (ISE) |
Location platform |
Cisco Connected Mobile Experiences (CMX), Cisco DNA Spaces |
Access points |
Aironet 802.11ac Wave 1 and Wave 2 access points, Cisco Catalyst 9100 802.11ax access points |
⠀
Physical dimensions |
Width |
17.3 inches (43.94 cm) |
Depth |
19.5 inches (49.53 cm) |
Height |
1.72 inches (4.37 cm) |
Weight |
22.8 lb (10.34 kg) |
⠀
Ports and their purpose |
1x RJ-45 console port |
Console port for out-of-band management |
|
1x USB 3.0 console port |
Console port for out-of-band management |
|
2x USB 3.0 ports |
USB 3.0 ports for plugging in external memory |
|
1x RJ-45 management port |
Management port used for out-of-band management. Also known as service port |
|
1x RJ-45 redundancy port |
Redundancy port used for SSO |
|
1x SFP Gigabit Ethernet redundancy port |
Redundancy port used for SSO ● Redundancy port used for SSO; works with Cisco supported SFPs (GLC-LH-SMD and GLC-SX-MMD) for RP port
|
|
4x 10G/1G SFP or SFP ports |
Ports used for sending and receiving traffic between access points and controller, northbound traffic, in-band management traffic, and wireless client traffic. Must be connected to the switch |
|
⠀
Front panel LEDs |
LED |
Color |
Function |
Power |
Green |
Green if all power rails are within spec |
System status |
Green |
On: IOS has boot complete Blinking: IOS boot in progress |
Amber |
On: System crash Off: ROMMON boot |
|
High Availability |
Green |
On: HA active |
Amber |
Slow blink: Booted with HA standby cold Fast blink: HA maintenance |
|
Alarm |
Green |
On: ROMMON boot complete Blinking: System upgrade in progress |
Amber |
On: ROMMON boot and SYSTEM bootup Blinking: Temperature err and secure boot failure |
|
USB console |
Green |
When LED is lit, USB Console is enabled (RJ-45 console is disabled) |
SSD activity |
Green |
Indicates active use of the hard disk SSD memory devices in the unit |
Network link |
Green |
Solid green indicates link Flashing green indicates activity |
⠀
Power LEDs |
Green LED |
Amber LED |
Power supply status |
Off |
Off |
No AC power to all power supplies |
Off |
On |
Power supply failure (includes over voltage, over current, over temperature, and fan failure) |
Off |
1 Hz blinking |
Power supply warning events in which the power supply continues to operate (high temperature, high power, and slow fan) |
1 Hz blinking |
Off |
AC present, 12VSB on (power supply off) |
On |
Off |
Power supply on and OK |
⠀
SFP support |
Type |
Modules supported |
Small Form-Factor Pluggable (SFP) |
GLC-BX-D |
GLC-BX-U |
|
GLC-LH-SMD |
|
GLC-SX-MMD |
|
GLC-ZX-SMD |
|
GLC-TE |
|
Enhanced SFP (SFP ) |
SFP-10G-SR |
SFP-10G-SR-S |
|
SFP-10G-SR-X |
|
SFP-10G-LR |
|
SFP-10G-LRM |
|
SFP-10G-LR-X |
|
SFP-10G-ER |
|
SFP-10G-ZR |
|
SFP-H10GB-ACU7M |
|
SFP-H10GB-ACU10M |
|
DWDM-SFP10G-30.33 — DWDM-SFP10G-61.41 |
⠀
Specifications |
Wireless standards |
IEEE 802.11a, 802.11b, 802.11g, 802.11d, WMM/802.11e, 802.11h, 802.11n, 802.11k, 802.11r, 802.11u, 802.11w, 802.11ac Wave1 and Wave2, 802.11ax |
|
Wired, switching, and routing standards |
IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX, 1000BASE-T. 1000BASE-SX, 1000-BASE-LH, IEEE 802.1Q VLAN tagging, 802.1AX Link Aggregation |
|
Data standards |
● RFC 768 User Datagram Protocol (UDP)
● RFC 791 IP
● RFC 2460 IPv6
● RFC 792 Internet Control Message Protocol (ICMP)
● RFC 793 TCP
● RFC 826 Address Resolution Protocol (ARP)
● RFC 1122 Requirements for Internet Hosts
● RFC 1519 Classless Interdomain Routing (CIDR)
● RFC 1542 Bootstrap Protocol (BOOTP)
● RFC 2131 Dynamic Host Configuration Protocol (DHCP)
● RFC 5415 Control and Provisioning of Wireless Access Points (CAPWAP) Protocol
● RFC 5416 CAPWAP Binding for 802.11
|
|
Security standards |
● Wi-Fi Protected Access (WPA)
● IEEE 802.11i (WPA2, RSN)
● Wi-Fi Protected Access 3 (WPA3)
● RFC 1321 MD5 Message-Digest Algorithm
● RFC 1851 Encapsulating Security Payload (ESP) Triple DES (3DES) Transform
● RFC 2104 HMAC: Keyed-Hashing for Message Authentication
● RFC 2246 TLS Protocol Version 1.0
● RFC 2401 Security Architecture for the Internet Protocol
● RFC 2403 HMAC-MD5-96 within ESP and AH
● RFC 2404 HMAC-SHA-1-96 within ESP and AH
● RFC 2405 ESP DES-CBC Cipher Algorithm with Explicit IV
● RFC 2407 Interpretation for Internet Security Association Key Management Protocol (ISAKMP)
● RFC 2408 ISAKMP
● RFC 2409 Internet Key Exchange (IKE)
● RFC 2451 ESP CBC-Mode Cipher Algorithms
● RFC 3280 Internet X.509 Public Key Infrastructure (PKI) Certificate and Certificate Revocation List (CRL) Profile
● RFC 4347 Datagram Transport Layer Security (DTLS)
● RFC 5246 TLS Protocol Version 1.2
|
|
Encryption standards |
● Static Wired Equivalent Privacy (WEP) RC4 40, 104 and 128 bits
● Advanced Encryption Standard (AES): Cipher Block Chaining (CBC), Counter with CBC-MAC (CCM), Counter with CBC Message Authentication Code Protocol (CCMP)
● Data Encryption Standard (DES): DES-CBC, 3DES
● Secure Sockets Layer (SSL) and Transport Layer Security (TLS): RC4 128-bit and RSA 1024- and 2048-bit
● DTLS: AES-CBC
● IPsec: DES-CBC, 3DES, AES-CBC
● 802.1AE MACsec encryption
|
|
Authentication, Authorization, and Accounting (AAA) standards |
● IEEE 802.1X
● RFC 2548 Microsoft Vendor-Specific RADIUS Attributes
● RFC 2716 Point-to-Point Protocol (PPP) Extensible Authentication Protocol (EAP)-TLS
● RFC 2865 RADIUS Authentication
● RFC 2866 RADIUS Accounting
● RFC 2867 RADIUS Tunnel Accounting
● RFC 2869 RADIUS Extensions
● RFC 3576 Dynamic Authorization Extensions to RADIUS
● RFC 5176 Dynamic Authorization Extensions to RADIUS
● RFC 3579 RADIUS Support for EAP
● RFC 3580 IEEE 802.1X RADIUS Guidelines
● RFC 3748 Extensible Authentication Protocol (EAP)
● Web-based authentication
● TACACS support for management users
|
|
Management standards |
● Simple Network Management Protocol (SNMP) v1, v2c, v3
● RFC 854 Telnet
● RFC 1155 Management Information for TCP/IP-based Internets
● RFC 1156 MIB
● RFC 1157 SNMP
● RFC 1213 SNMP MIB II
● RFC 1350 Trivial File Transfer Protocol (TFTP)
● RFC 1643 Ethernet MIB
● RFC 2030 Simple Network Time Protocol (SNTP)
● RFC 2616 HTTP
● RFC 2665 Ethernet-Like Interface Types MIB
● RFC 2674 Definitions of Managed Objects for Bridges with Traffic Classes, Multicast Filtering, and Virtual Extensions
● RFC 2819 Remote Monitoring (RMON) MIB
● RFC 2863 Interfaces Group MIB
● RFC 3164 Syslog
● RFC 3414 User-Based Security Model (USM) for SNMPv3
● RFC 3418 MIB for SNMP
● RFC 3636 Definitions of Managed Objects for IEEE 802.3 MAUs
● RFC 4741 Base NETCONF protocol
● RFC 4742 NETCONF over SSH
● RFC 6241 NETCONF
● RFC 6242 NETCONF over SSH
● RFC 5277 NETCONF event notifications
● RFC 5717 Partial Lock Remote Procedure Call
● RFC 6243 With-Defaults capability for NETCONF
● RFC 6020 YANG
● Cisco private MIBs
|
|
Management interfaces |
● Web-based: HTTP/HTTPS
● Command-line interface: Telnet, Secure Shell (SSH) Protocol, serial port
● SNMP
● NETCONF
|
|
Hard disk drives (HDD) |
● SATA solid-state drive (SSD)
● 240 GB of memory
|
|
Environmental conditions supported |
Operating temperature: ● Normal: 0° to 40°C (32° to 104°F)
● Short term:0° to 50°C (32° to 122°F)
Nonoperating temperature: ● -40°to 65°C (-104° to 149°F)
Operating humidity: ● Nominal: 10% to 90% noncondensing
● Short term: 5% to 90% noncondensing
Nonoperating temperature humidity: ● 5% to 93% at 82°F (28°C)
Operating altitude: ● Appliance operating: 0 to 3000 m (0 to 10,000 ft)
● Appliance nonoperating: 0 to 12,192 m (0 to 40,000 ft)
Electrical input: ● AC input frequency range: 47 to 63 Hz
● AC input range: 90 to 264 VAC with AC PEM
● 1100W AC with optional redundant power supply (hot-swappable)
Maximum power: 381W Heat dissipation: 1300 BTU/hr Sound power level measure: ● A-weighted sound power level is 74.1 LpAm (dBA) @ 27C nominal operation
|
|
Regulatory compliance |
Safety: ● UL/CSA 60950-1
● IEC/EN 60950-1
● AS/NZS 60950.1
● CAN/CSA-C22.2 No. 60950-1
|
|
EMC – Emissions: ● FCC 47CFR15
● AS/NZS CISPR 22
● CISPR 22
● EN55022/EN55032 (EMI-1)
● ICES-003
● VCCI
● KN 32 (EMI-2)
● CNS-13438
|
Class A |
|
EMC – Emissions: ● EN61000-3-2 Power Line Harmonics (EMI-3)
● EN61000-3-3 Voltage Changes, Fluctuations, and Flicker (EMI-3)
|
|
|
EMC – Immunity: ● IEC/EN61000-4-2 Electrostatic Discharge Immunity
● IEC/EN61000-4-3 Radiated Immunity
● IEC/EN61000-4-4 EFT-B Immunity (AC Power Leads)
● IEC/EN61000-4-4 EFT-B Immunity (DC Power Leads)
● IEC/EN61000-4-4 EFT-B Immunity (Signal Leads)
● IEC/EN61000-4-5 Surge AC Port
● IEC/EN61000-4-5 Surge DC Port
● IEC/EN61000-4-5 Surge Signal Port
● IEC/EN61000-4-6 Immunity to Conducted Disturbances
● IEC/EN61000-4-8 Power Frequency Magnetic Field Immunity
● IEC/EN61000-4-11 Voltage Dips, Short Interruptions, and Voltage Variations
● K35 (EMI-2)
|
|
|
|
EMC (ETSI/EN) ● EN 300 386 Telecommunications Network Equipment (EMC) (EMC-3)
● EN55022 Information Technology Equipment (Emissions)
● EN55024/CISPR 24 Information Technology Equipment (Immunity)
● EN50082-1/EN61000-6-1 Generic Immunity Standard (EMC-4)
|
|