C9300L-48P-4G-A Catalyst 9300 48-port fixed uplinks PoE+, 4X1G uplinks, Network Advantage

282,287.52

Fan

Primary Power Supply

Secondary Power Supply

Power Cables

Stack Module

Console Cables

Storage Module

Subscription License

SmartNet

Сумма:

Add-ons total:

Всего:

Вес: 9 kg
Объем: 0.0505 m3
Размеры упаковки (HxWxL): 15x58x58 cm
скачать как CSV

Platform details

FRU Power Supply

FRU Fans

Modular Uplinks

Stacking Bandwidth Support

Cisco StackPower

Catalyst 9800 Embedded WLC

SD-Access Support

320 Gbps

Yes (50 APs)

Yes (256 Virtual Networks)

 

Configurations

Total 10/100/1000, Multigigabit copper or SFP Fiber

Uplink Configuration

Default AC power supply

48 PoE

4x 1G fixed uplinks

715WAC

 

Power supply

Default power supply

Available PoE power

With 350W Secondary PS

With 715W Secondary PS

With 1100W Secondary PS

PWR-C1-715WAC-P***

505W

855W

1220W

1440W*

 

Supported stacking options

Stacking support

Stacking bandwidth support

Optional Stacking hardware

Number of members

Supported stack members

StackWise-320

320 Gbps

C9300L-STACK-KIT

8

Other C9300L SKUs with same license level

 

Performance specifications

Total number of MAC addresses

32,000

Total number of IPv4 routes (ARP plus learned routes)

32,000 (24,000 direct routes and 8000 indirect routes)

IPv6 routing entries

16,000

Multicast routing scale

8,000

QoS scale entries

5,120

ACL scale entries

5,120

Packet buffer per SKU

16 MB buffer for 24 and 48 port Gigabit Ethernet models

FNF entries

64,000 flow on 24- and 48-port Gigabit Ethernet models

DRAM

8 GB

Flash

16 GB

VLAN IDs

4094

Total Switched Virtual Interfaces (SVIs)

1000

Jumbo frames

9198 bytes

Total routed ports per Catalyst 9300 Series stack

416

 

Bandwidth specifications

Switching capacity

Switching capacity with stacking

Forwarding rate

Forwarding rate with stacking

104 Gbps

424 Gbps

77.38 Mpps

315.48 Mpps

 

Dimensions, Weight, and Mean Time between failures metrics

General Specifications

Dimensions (H x W x D) inches

Chassis only

W/ Default Power Supply

W/ 1100W Power Supply

1.73 X 17.5 X 16.1

1.73 X 17.5 X 17.7

1.73 X 17.5 X 19.2

Dimensions (H x W x D) Cms

4.4 x 44.5 x 40.9

4.4 x 44.5 x 44.9

4.4 x 44.5 x 48.8

Weight (with default power supply)

Pounds

Kilograms

15.46

7.03

Mean Time Between Failures – MTBF (hours)

314,140

PWR-C1-715WAC-P

1,054,881 (ranges from 1.05M to 2.6M depending on temperature, input voltage and vendor)

 

Environmental ranges

Acoustic noise

Measured per ISO 7779 and declared per ISO 9296

Bystander positions operating to an ambient temperature of 25°C

With AC power supply (with 24 PoE ports loaded for C9300 SKUs)

● LpA: 45dB typical, 48 dB max
● LwA: 5.6B typical, 5.9B max

With AC power supply (with half the number of PoE ports loaded for C9300L SKUs)

● LpA: 44dB typical, 47 dB max
● LwA: 5.5B typical, 5.8B max

Typical: Noise emission for a typical configuration

Maximum: Statistical maximum to account for variation in production

 

Connectors

Connectors and cabling

● 1000BASE-T ports: RJ-45 connectors, 4-pair Cat 5E UTP cabling
● Multigigabit-T ports: RJ-45 connectors, 4-pair Cat 5E, Cat 6, Cat 6A UTP cabling
● 1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Cat 5E UTP cabling
● SFP transceivers: LC fiber connectors (single-mode or multimode fiber)
● SFP transceivers: LC fiber connectors (single-mode or multimode fiber)
● QSFP transceivers: MPO and LC fiber connectors (single-mode or multimode fiber)
● QSFP connector
● SFP connector
● Cisco StackWise stacking ports: copper-based Cisco StackWise cabling
● Cisco StackPower: Cisco proprietary power stacking cables
● Ethernet management port: RJ-45 connectors, 4-pair Cat 5 UTP cabling
● Management console port: RJ-45-to-DB9 cable for PC connections

Power connectors

● Customers can provide power to a switch by using the internal power at the back of the switch
● Internal power supply connector: The internal power supply is an auto-ranging unit. It supports input voltages between 100 (115 for 1100WAC) and 240 VAC. Use the supplied AC power cord to connect the AC power connector to an AC power outlet

 

Management and standards support*

Description

Specification

Management

BRIDGE-MIB

CISCO-BRIDGE-EXT-MIB

CISCO-BULK-FILE-MIB

CISCO-CABLE-DIAG-MIB

CISCO-CALLHOME-MIB

CISCO-CEF-MIB

CISCO-CIRCUIT-INTERFACE-MIB

CISCO-CONFIG-COPY-MIB

CISCO-CONFIG-MAN-MIB

CISCO-DEVICE-LOCATION-MIB

CISCO-DHCP-SNOOPING-MIB

CISCO-EIGRP-MIB

CISCO-EMBEDDED-EVENT-MGR-MIB

CISCO-ENTITY-FRU-CONTROL-MIB

CISCO-ENTITY-SENSOR-MIB

CISCO-ENTITY-VENDORTYPE-OID-MIB

CISCO-ERR-DISABLE-MIB

CISCO-FLASH-MIB

CISCO-FLOW-MONITOR-MIB

CISCO-FTP-CLIENT-MIB

CISCO-HSRP-EXT-MIB

CISCO-HSRP-MIB

CISCO-IETF-BFD-MIB

CISCO-IETF-PPVPN-MPLS-VPN-MIB

CISCO-IETF-PW-MPLS-MIB

CISCO-IF-EXTENSION-MIB

CISCO-IGMP-FILTER-MIB

CISCO-IMAGE-LICENSE-MGMT-MIB

CISCO-IMAGE-MIB

CISCO-IP-CBR-METRICS-MIB

CISCO-IP-STAT-MIB

CISCO-IP-TAP-MIB

CISCO-IP-URPF-MIB

CISCO-IPSEC-FLOW-MONITOR-MIB

CISCO-IPSEC-MIB

CISCO-IPSEC-PROVISIONING-MIB

CISCO-IPSLA-AUTOMEASURE-MIB

CISCO-IPSLA-ECHO-MIB

CISCO-IPSLA-JITTER-MIB

CISCO-L2-CONTROL-MIB

CISCO-L2L3-INTERFACE-CONFIG-MIB

CISCO-LAG-MIB

CISCO-LICENSE-MGMT-MIB

CISCO-LOCAL-AUTH-USER-MIB

CISCO-MAC-NOTIFICATION-MIB

CISCO-MDI-METRICS-MIB

CISCO-MEDIA-METRICS-MIB

CISCO-MEMORY-POOL-MIB

CISCO-MPLS-LSR-EXT-STD-MIB

CISCO-NBAR-PROTOCOL-DISCOVERY-MIB

CISCO-NHRP-EXT-MIB

CISCO-NTP-MIB

CISCO-PAGP-MIB

CISCO-PORT-SECURITY-MIB

CISCO-PORT-STORM-CONTROL-MIB

CISCO-POWER-ETHERNET-EXT-MIB

CISCO-PRIVATE-VLAN-MIB

CISCO-PROCESS-MIB

CISCO-PRODUCTS-MIB

CISCO-RF-MIB

CISCO-RTP-METRICS-MIB

CISCO-RTTMON-ICMP-MIB

CISCO-STACKWISE-MIB

CISCO-STP-EXTENSIONS-MIB

CISCO-SYSLOG-MIB

CISCO-TCP-MIB

CISCO-UDLDP-MIB

CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB

ENTITY-MIB

HC-ALARM-MIB

HC-RMON-MIB

IEEE8023-LAG-MIB

IF-MIB

IP-FORWARD-MIB

IP-MIB

LLDP-EXT-MED-MIB

LLDP-MIB

MAU-MIB

MPLS-L3VPN-STD-MIB

MPLS-LSR-STD-MIB

MPLS-VPN-MIB

OLD-CISCO-CHASSIS-MIB

OLD-CISCO-CPU-MIB

OLD-CISCO-INTERFACES-MIB

OLD-CISCO-IP-MIB

OLD-CISCO-MEMORY-MIB

OLD-CISCO-SYS-MIB

OLD-CISCO-TCP-MIB

OLD-CISCO-TS-MIB

POWER-ETHERNET-MIB

RFC1213-MIB

RMON-MIB

RMON2-MIB

SMON-MIB

SNMPv2-MIB

SONET-MIB

TCP-MIB

UDP-MIB

Standards

IEEE 802.1s

IEEE 802.1w

IEEE 802.1x

IEEE 802.1x-Rev

IEEE 802.3ad

IEEE 802.3ae

IEEE 802.3af

IEEE 802.3at

IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports

IEEE 802.1D Spanning Tree Protocol

IEEE 802.1p CoS prioritization

IEEE 802.1Q VLAN

IEEE 802.3 10BASE-T specification

IEEE 802.3u 100BASE-TX specification

IEEE 802.3ab 1000BASE-T specification

IEEE 802.3z 1000BASE-X specification

IEEE 802.3bz Multirate 2.5G/5G specification

IEEE 802.3an 10G BASE-T specification

RMON I and II standards

SNMPv1, v2c, and v3

 

Power specifications

PWR-C1-715WAC**

Power supply rated maximum

715W

Total output BTU (note: 1000 BTU/hr = 293W)

2465 BTU/hr, 715W

Input-voltage range and frequency

100 to 240 VAC,

50 to 60 Hz

Input current

10-5A

Output ratings

-56V at 12.8A

Output holdup time

16.7 ms minimum at 100VAC

Power-supply input receptacles

IEC 320-C16

(IEC60320-C16)

Power cord rating

15A

Physical specifications

(H x W x D): 1.58 x 3.25 x 12.20 in

Weight: 2.6 lb (1.2 kg)

 

Power specifications – platinum rated power supplies

*PWR-C1-715WAC-P

Power supply rated maximum output power

715W

Total output BTU
(note: 1000 BTU/hr = 293W)

2440 BTU/hr, 715W

Input-voltage range and frequency

100 to 240 VAC,

50 to 60 Hz

Input current

10-5A

Output ratings

-56V at 12.8A

Output holdup time

20 ms minimum at 100VAC

Power-supply input receptacles

IEC 320-C16

(IEC60320-C16)

Power cord rating

15A

Physical specifications

(H x W x D): 1.58 x 3.25 x 12.20 in

Weight: 2.6 lb (1.2 kg)

Operating temperature

Normal operating temperature* and altitudes:

● -5°C to 45°C, up to 5000 feet (1500m)
● -5°C to 40°C, up to 10,000 feet (3000m)

*Minimum ambient temperature for cold start is 32°F (0°C)

Short-term* exceptional conditions:

● -5°C to 50°C, up to 5000 feet (1500m)
● -5°C to 45°C, up to 10,000 feet (3000m)
● -5°C to 45°C, at sea level with single fan failure

*Not more than following in one-year period: 96 consecutive hours, or 360 hours total, or 15 occurrences

Storage temperature

-40° to 158°F (-40° to 70°C)

Relative humidity operating and nonoperating noncondensing

5% to 90% noncondensing

Altitude

10,000 ft. (3000 meters), up to 45°C

EMI and EMC compliance

FCC Part 15 (CFR 47) Class A

ICES-003 Class A

EN 55032 Class A

CISPR 32 Class A

AS/NZS 3548 Class A

BSMI Class A (AC input models only)

VCCI Class A

EN 55024, EN300386, EN 61000-3-2, EN 61000-3-3

EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN 61000-6-1

Safety compliance

LED indicators

“AC OK”: Input power to the power supply is OK

“PS OK”: Output power from the power supply is OK

 

Safety and compliance information

Safety certifications

● UL 60950-1
● CAN/CSA-C222.2 No. 60950-1
● EN 60950-1
● IEC 60950-1
● AS/NZS 60950.1
● IEEE 802.3

Electromagnetic emissions certifications

● 47 CFR Part 15
● CISPR22 Class A
● EN 300 386 V1.6.1
● EN 55022 Class A
● EN 55032 Class A
● CISPR 32 Class A
● EN61000-3-2
● EN61000-3-3
● ICES-003 Class A
● TCVN 7189 Class A
● V-3 Class A
● CISPR24
● EN 300 386
● EN55024
● TCVN 7317
● V-2/2015.04
● V-3/2015.04
● CNS13438
● KN32
● KN35
● IEC 61000-6-1
● EN 61000-6-1

Additional Certifications for C9300L SKUs:

● QCVN 118:2018/BTTTT
● CISPR24/25
● CISPR 32 Class A
● VCCI-CISPR 32 Class A
● EN55035

Environmental

Reduction of Hazardous Substances (ROHS) 5