C9200-48PB-A Catalyst 9200 48-port PoE+, enhanced VRF, Network Advantage

4,987.62$

Network Module

Stack Module

Secondary Power Supply

Console Cables

Power Cables

Subscription License

SmartNet

Сумма:

Add-ons total:

Всего:

Вес: 8 kg
Объем: 0.0505 m3
Размеры упаковки (HxWxL): 15x58x58 cm
скачать как CSV

Platform details

Models

FRU Power Supply

FRU Fans

Modular Uplinks

Stacking Bandwidth Support

SD-Access Support 1

Modular uplink models (C9200 Enhanced VN SKUs)

160 Gbps

Yes (32 Virtual Networks)2

 

Configurations

Downlinks total 10/100/1000 or PoE copper ports

Uplink configuration

Default primary AC power supply

Fans

48 ports full PoE

Modular uplink options

PWR-C6-1KWAC

FRU redundant

 

Power supply

Default primary power supply

Available PoE power with single primary power supply only*

Optional secondary power supply

Available PoE power with additional secondary power supply*

PWR-C6-1KWAC

740W

PWR-C6-1KWAC

1440W

 

Supported stacking options

Model

Stacking support

Stacking bandwidth support

Stacking hardware

Number of members

Supported stack members

Modular models (C9200 SKUs)

StackWise®-160

160 Gbps

C9200-STACK-KIT

8

Other C9200 models with same license level

 

Performance specifications

Virtual Networks

4 for C9200-24T, C9200-24P, C9200-48T, C9200-48P, C9200-24PXG, C9200-48PXG, C9200-48PL

32 for C9200-24PB, C9200-48PB

Stacking bandwidth

160 Gbps

Total number of MAC addresses

32,000

Total number of IPv4 routes (ARP plus learned routes)

14,000 (10,000 direct routes and 4,000 indirect routes)

IPv4 routing entries

4,000

IPv6 routing entries

2,000

Multicast routing scale

1,000

QoS scale entries

1,000

ACL scale entries

1,600

Packet buffer per SKU

6 MB buffers for 24- or 48-port Gigabit Ethernet models , 12MB buffers for 24 or 48 port multigigabit models

Flexible NetFlow (FNF) entries

16,000 flows on 24- and 48-port Gigabit Ethernet models

DRAM

4 GB

Flash

4 GB

VLAN IDs

4094

PVST Instances

128

STP Virtual Ports (Port * VLANs) for PVST

13,000

STP Virtual Ports (Port * VALNs) for MST

13,000

Total Switched Virtual Interfaces (SVIs)

1000

Jumbo frames

9198 bytes

Wireless bandwidth per switch

Up to 48 Gbps on 24-port and 48-port Gigabit Ethernet model

IP SGT binding scale

8K

Number of IPv4 bindings

8K

Number of SGT/DGT policies

2K

Number of SXP Sessions

200

 

Bandwidth specifications

Switching capacity

Switch capacity with Stacking

Forwarding rate

Forwarding rate with Stacking

176 Gbps

336 Gbps

130.95 Mpps

250 Mpps

 

Dimensions, Weight, and Mean Time between failures metrics

General Specifications (HxWxD)

Chassis Dimensions

Chassis FEP Fan Dimensions (HxWxD)

Inches

Centimeters

Inches

Centimeters

1.73 x 17.5 x 13.8

4.4 x 44.5 x 35.0

1.73 x 17.5 x 15.4

4.4 x 44.5 x 39.1

Weight (with default power supply)

Pounds

Kilograms

12.12

5.5

Mean Time Between Failures – MTBF (hours)

384,980

PWR-C6-1KWAC

1,600,060

 

Environmental ranges

Acoustic noise

Measured per ISO 7779 and declared per ISO 9296

Bystander positions operating to an ambient temperature of 25°C

With AC power supply (with 24 PoE ports loaded):

● LpA: 42dB typical, 45 dB max
● LwA: 5.3B typical, 5.6B max

Typical: Noise emission for a typical configuration

Maximum: Statistical maximum to account for variation in production

 

Connectors

Connectors and cabling

● 1000BASE-T ports: RJ-45 connectors, 4-pair Cat 5E UTP cabling
● 1000BASE-T SFP-based ports: RJ-45 connectors, 4-pair Cat 5E UTP cabling
● 100BASE-FX, 1000BASE-SX, -LX/LH, -ZX, -BX10, dense wavelength-division multiplexing (DWDM) and Coarse Wavelength-Division Multiplexing (CWDM) SFP transceivers: LC fiber connectors (single-mode or multimode fiber)
● 10GBASE-SR, LR, LRM (only C9200), ER, ZR, DWDM SFP transceivers: LC fiber connectors (single-mode or multimode fiber)
● SFP connector
● Cisco StackWise-160/80 stacking ports: copper-based Cisco StackWise cabling
● Ethernet management port: RJ-45 connectors, 4-pair Cat 5 UTP cabling
● Management console port: RJ-45-to-DB9 cable for PC connections, USB-C adaptor, USB adaptor

Power connectors

● Internal power supply connector: The internal power supply is an auto-ranging unit. It supports input voltages between 100 and 240 VAC. Use the supplied AC power cord to connect the AC power connector to an AC power outlet.

 

Management and standards support*

Description

Specification

Management

BRIDGE-MIB

CISCO-BRIDGE-EXT-MIB

CISCO-BULK-FILE-MIB

CISCO-CABLE-DIAG-MIB

CISCO-CALLHOME-MIB

CISCO-CEF-MIB

CISCO-CIRCUIT-INTERFACE-MIB

CISCO-CONFIG-COPY-MIB

CISCO-CONFIG-MAN-MIB

CISCO-DEVICE-LOCATION-MIB

CISCO-DHCP-SNOOPING-MIB

CISCO-EIGRP-MIB

CISCO-EMBEDDED-EVENT-MGR-MIB

CISCO-ENTITY-FRU-CONTROL-MIB

CISCO-ENTITY-SENSOR-MIB

CISCO-ENTITY-VENDORTYPE-OID-MIB

CISCO-ERR-DISABLE-MIB

CISCO-FLASH-MIB

CISCO-FLOW-MONITOR-MIB

CISCO-FTP-CLIENT-MIB

CISCO-HSRP-EXT-MIB

CISCO-HSRP-MIB

CISCO-IETF-BFD-MIB

CISCO-IETF-PPVPN-MPLS-VPN-MIB

CISCO-IETF-PW-MPLS-MIB

CISCO-IF-EXTENSION-MIB

CISCO-IGMP-FILTER-MIB

CISCO-IMAGE-LICENSE-MGMT-MIB

CISCO-IMAGE-MIB

CISCO-IP-CBR-METRICS-MIB

CISCO-IP-STAT-MIB

CISCO-IP-TAP-MIB

CISCO-IP-URPF-MIB

CISCO-IPSEC-FLOW-MONITOR-MIB

CISCO-IPSEC-MIB

CISCO-IPSEC-PROVISIONING-MIB

CISCO-IPSLA-AUTOMEASURE-MIB

CISCO-IPSLA-ECHO-MIB

CISCO-IPSLA-JITTER-MIB

CISCO-L2-CONTROL-MIB

CISCO-L2L3-INTERFACE-CONFIG-MIB

CISCO-LAG-MIB

CISCO-LICENSE-MGMT-MIB

CISCO-LOCAL-AUTH-USER-MIB

CISCO-MAC-NOTIFICATION-MIB

CISCO-MDI-METRICS-MIB

CISCO-MEDIA-METRICS-MIB

CISCO-MEMORY-POOL-MIB

CISCO-MPLS-LSR-EXT-STD-MIB

CISCO-NBAR-PROTOCOL-DISCOVERY-MIB

CISCO-NHRP-EXT-MIB

CISCO-NTP-MIB

CISCO-PAGP-MIB

CISCO-PORT-SECURITY-MIB

CISCO-PORT-STORM-CONTROL-MIB

CISCO-POWER-ETHERNET-EXT-MIB

CISCO-PRIVATE-VLAN-MIB

CISCO-PROCESS-MIB

CISCO-PRODUCTS-MIB

CISCO-RF-MIB

CISCO-RTP-METRICS-MIB

CISCO-RTTMON-ICMP-MIB

CISCO-STACKWISE-MIB

CISCO-STP-EXTENSIONS-MIB

CISCO-SYSLOG-MIB

CISCO-TCP-MIB

CISCO-UDLDP-MIB

CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB

ENTITY-MIB

HC-ALARM-MIB

HC-RMON-MIB

IEEE8023-LAG-MIB

IF-MIB

IP-FORWARD-MIB

IP-MIB

LLDP-EXT-MED-MIB

LLDP-MIB

MAU-MIB

MPLS-L3VPN-STD-MIB

MPLS-LSR-STD-MIB

MPLS-VPN-MIB

OLD-CISCO-CHASSIS-MIB

OLD-CISCO-CPU-MIB

OLD-CISCO-INTERFACES-MIB

OLD-CISCO-IP-MIB

OLD-CISCO-MEMORY-MIB

OLD-CISCO-SYS-MIB

OLD-CISCO-TCP-MIB

OLD-CISCO-TS-MIB

POWER-ETHERNET-MIB

RFC1213-MIB

RMON-MIB

RMON2-MIB

SMON-MIB

SNMPv2-MIB

SONET-MIB

TCP-MIB

UDP-MIB

Standards

EEE 802.1s

IEEE 802.1w

IEEE 802.1x

IEEE 802.1x-Rev

IEEE 802.3ad

IEEE 802.3af

IEEE 802.3at

IEEE 802.3x full duplex on 10BASE-T, 100BASE-TX, and 1000BASE-T ports

IEEE 802.1D Spanning Tree Protocol

IEEE 802.1p CoS prioritization

IEEE 802.1Q VLAN

IEEE 802.3 10BASE-T specification

IEEE 802.3u 100BASE-TX specification

IEEE 802.3ab 1000BASE-T specification

IEEE 802.3z 1000BASE-X specification

IEEE 802.1AE — 128-bit AES MACsec inter network device encryption with MACsec Key Agreement (MKA)

IEEE 802.3bz (for mGig PKG SKU’s only)

IEEE 802.3an (10GBase-T) (for mGig PKG SKU’s only)

RMON I and II standards

SNMPv1, v2c, and v3

 

Power specifications

PWR-C6-1KWAC

Power supply rated maximum

1000W

Total output BTU
(note: 1000 BTU/hr = 293W)

3412 BTU/hr, 1000W

Input-voltage range and frequency

100 to 240 VAC,

50 to 60 Hz

Input current

12-6A

Output ratings

54V at 16.5A

Output holdup time

20 ms minimum at 100 VAC

Power-supply input receptacles

IEC 320-C16

(IEC60320-C16)

Power cord rating

15A

Physical specifications

(H x W x D): 1.58” x 4.0” x 7.6”

Weight: 2 lb (0.9 kg)

Supported Product Family

C9200

Operating temperature

Normal operating temperature* and altitudes:

● -5°C to 45°C, up to 5000 feet (1500m)
● -5°C to 40°C, up to 10,000 feet (3000m)

* Minimum ambient temperature for cold start is 32°F (0°C)

Short-term* exceptional conditions:

● -5°C to 50°C, up to 5000 feet (1500m)
● -5°C to 45°C, up to 10,000 feet (3000m)
● -5°C to 45°C, at sea level with single fan failure

* Not more than following in one-year period: 96 consecutive hours, or 360 hours total, or 15 occurrences

Storage temperature

-40° to 158°F (-40° to 70°C)

Relative humidity operating and nonoperating noncondensing

5% to 90% noncondensing

Altitude

10,000 ft. (3000 meters), up to 45°C

EMI and EMC compliance

FCC Part 15 (CFR 47) Class A

ICES-003 Class A

EN 55032 Class A

CISPR 32 Class A

AS/NZS 3548 Class A

BSMI Class A

VCCI Class A

CISPR 35

EN 55024, EN300 386*, EN 61000-3-2, EN 61000-3-3

EN 61000-6-1

Safety compliance

UL 60950-1, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, CCC, CE Marking

LED indicators

“AC OK”: Input power to the power supply is OK

“PS OK”: Output power from the power supply is OK

 

Safety and compliance information

Safety certifications

● IEC 60950-1
● UL 60950-1
● CAN/CSA C22.2 No. 60950-1
● EN 60950-1
● AS/NZS 60950.1
● Class I Equipment

Electromagnetic emissions certifications

● 47 CFR Part 15
● CISPR 22 Class A
● CISPR 32 Class A
● CNS 13438
● EN 300 386 *
● EN 55022 Class A
● EN 55032 Class A
● EN61000-3-2
● EN61000-3-3
● ICES-003 Class A
● KN 32
● TCVN 7189 Class A
● V-3 Class A
● CISPR 24
● EN 300 386 *
● EN 55024
● KN 35
● TCVN 7317

Environmental

Reduction of Hazardous Substances (ROHS) 5